NIM Server Configuration
Refer to the “Advanced NIM Configuration Tasks” chapter of the
AIX 5L Installation Guide and Reference
,
order number SC23-4389, for information about doing the following:
v
Registering a client on the NIM server
v
Enabling a client to run diagnostics from the NIM server
Documentation for the AIX operating system is available from the IBM
Eserver
pSeries Information
Center at http://publib16.boulder.ibm.com/pseries/en_US/infocenter/base. Select
AIX documentation
. The
AIX Documentation
CD contains the base set of publications for the operating system, including
system-management and end-user documentation.
To verify that the client system is registered on the NIM server and the diagnostic boot is enabled, run the
lsnim -a Cstate -Z
ClientName
command from the command line on the NIM server. Refer to the
following table for system responses.
Note:
The
ClientName
is the name of the system on which you want to run standalone diagnostics.
System Response
Client Status
#name:Cstate:
ClientName:diagnostic boot has been
enabled:
The client system is registered on the NIM server and
enabled to run diagnostics from the NIM server.
#name:Cstate:
ClientName:ready for a NIM operation:
or
#name:Cstate:
ClientName:BOS installation has been
enabled:
The client is registered on the NIM server but not enabled
to run diagnostics from the NIM server.
Note:
If the client system is registered on the NIM server
but Cstate has not been set, no data will be returned.
0042-053 lsnim: there is no NIM object
named "ClientName"
The client is not registered on the NIM server.
Client Configuration and Booting Standalone Diagnostics from the NIM
Server
To run standalone diagnostics on a client from the NIM server, do the following:
1. Remove any removable media (tape or CD-ROM disc).
2. Stop all programs including the operating system (get help if needed).
3.
If you are running standalone diagnostics in a full system partition, verify with the system administrator
and system users that the system unit can shut down. Stop all programs, including the operating
system. Refer to the operating system documentation for
shutdown
command information.
In a partitioned system, make the CD-ROM drive available to the partition used to run standalone
diagnostics (refer to the
IBM Hardware Management Console for pSeries Installation and Operations
Guide
for more information). Verify with the system administrator and system users using that partition
that all applications on that partition must be stopped, and that the partition will be rebooted. Stop all
programs on that partition, including the operating system.
4. If you are in a full system partition, power on the system unit to run standalone diagnostics. In a
partitioned system, reboot the partition to run standalone diagnostics.
5. When the keyboard indicator is displayed (the word
keyboard
), press the number 1 key on the
keyboard to display the SMS menu.
6. Enter any requested passwords.
7. Select
Setup Remote IPL (Initial Program Load)
.
Chapter 2. Verifying the Hardware Operation
19
Содержание 9114-275 - IntelliStation POWER 275
Страница 1: ...IntelliStation POWER 9114 Model 275 Installation Guide SA38 0634 00...
Страница 2: ......
Страница 3: ...IntelliStation POWER 9114 Model 275 Installation Guide SA38 0634 00...
Страница 8: ...vi IntelliStation POWER 9114 Model 275 Installation Guide...
Страница 12: ...x IntelliStation POWER 9114 Model 275 Installation Guide...
Страница 14: ...xii IntelliStation POWER 9114 Model 275 Installation Guide...
Страница 80: ...64 IntelliStation POWER 9114 Model 275 Installation Guide...
Страница 82: ...66 IntelliStation POWER 9114 Model 275 Installation Guide...
Страница 84: ...68 IntelliStation POWER 9114 Model 275 Installation Guide...
Страница 92: ...76 IntelliStation POWER 9114 Model 275 Installation Guide...
Страница 98: ...82 IntelliStation POWER 9114 Model 275 Installation Guide...
Страница 101: ......
Страница 102: ...Part Number 00P5944 Printed in U S A SA38 0634 00 1P P N 00P5944...