System-error
log
message
Action
Fan
X
not
detected
(X
of
1-8)
1.
Make
sure
that
nothing
is
blocking
the
fan
or
power
supply.
2.
Check
the
physical
connection
and
make
sure
that
the
fan
is
correctly
seated.
3.
Replace
fan
X.
Front
Panel
is
not
plugged
in
1.
Make
sure
that
the
operator
information
panel
cables
are
correctly
connected
(verify
LED
activity).
2.
Replace
the
operator
information
panel.
Hard
Drive
X
Fault
1.
Run
diagnostics.
2.
Hard
disk
drive
3.
SAS
backplane
Hard
drive
X
removal
detected
Reseat
hard
disk
drive
X
and
restart
the
server.
Hostname
set
to
<value>
by
user
<USERID>
Information
only
Hot
plug
card
is
not
plugged
in
1.
Make
sure
that
the
PCI
cables
are
correctly
connected.
2.
Reseat
the
failing
hot-plug
cable
or
adapter.
3.
Replace
the
failing
hot-plug
cable
or
adapter.
Hurricane
SMI
1.2V
Power
Good
Fault
1.
Reseat
the
microprocessor
tray.
2.
Reseat
the
memory
cards.
3.
(Trained
service
technician
only)
Replace
the
microprocessor
tray.
Hurricane
Vtt
MR
1.5V
Power
Good
Fault
1.
Reseat
the
microprocessor
tray.
2.
Reseat
the
memory
cards.
3.
(Trained
service
technician
only)
Replace
the
microprocessor
tray.
Hvtt
IB
1.8V
Power
Good
Fault
1.
Reseat
the
microprocessor
tray.
2.
Reseat
the
memory
cards.
3.
(Trained
service
technician
only)
Replace
the
microprocessor
tray.
Hvtr
IB
2.5V
Power
Good
Fault
1.
Reseat
the
microprocessor
tray.
2.
Reseat
the
memory
cards.
3.
(Trained
service
technician
only)
Replace
the
microprocessor
tray.
I/O
Card
Power
Good
Fault
1.
Reseat
the
Remote
Supervisor
Adapter
II
SlimLine,
if
present.
2.
Reseat
the
I/O
board.
3.
Replace
the
I/O
board.
4.
(Trained
service
technician
only)
Replace
the
PCI
board.
Chapter
5.
Diagnostics
135
Содержание 88643RU - System x3850 - 8864
Страница 1: ...IBM System x3850 Type 8864 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...IBM System x3850 Type 8864 Problem Determination and Service Guide...
Страница 8: ...vi IBM System x3850 Type 8864 Problem Determination and Service Guide...
Страница 28: ...12 IBM System x3850 Type 8864 Problem Determination and Service Guide...
Страница 38: ...22 IBM System x3850 Type 8864 Problem Determination and Service Guide...