System-error
log
message
Action
Power
supply
current
exceeded
max
spec
value
1.
Install
another
power
supply
(if
possible)
and
make
sure
that
ac
power
cords
are
correctly
connected.
2.
Remove
devices
that
consume
an
extraordinary
amount
of
power.
3.
Replace
the
power
backplane.
Power
Supply
X
12V
Over
Current
Fault
1.
Power
supply
2.
Power
backplane
Power
Supply
X
12V
Over
Voltage
Fault
1.
Power
supply
2.
Power
backplane
Power
Supply
X
12V
Under
Voltage
Fault
1.
Power
supply
2.
Power
backplane
Power
Supply
X
AC
Power
Removed
1.
Connect
the
ac
power
cord
to
power
supply
X.
2.
Replace
power
supply
X.
Power
Supply
X
Current
Fault
1.
Power
supply
2.
Power
backplane
Power
Supply
X
DC
Good
Fault
1.
If
the
system
power
present
LED
is
lit,
reduce
the
server
to
the
minimum
configuration
(see
page
156)
and
replace
components
one
at
a
time
to
isolate
the
fault.
2.
Reseat
the
following
components:
a.
Power
supply
b.
Power
backplane
3.
Replace
the
components
listed
in
step
2
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
Power
Supply
X
Removed
1.
Reseat
power
supply
X.
2.
Replace
power
supply
X.
3.
Replace
the
power
backplane.
Power
Supply
X
Temperature
Fault
1.
Make
sure
that
the
fan
air
intake
areas
are
clear
and
well
ventilated.
2.
Make
sure
that
all
fans
are
installed
and
functioning.
3.
Reseat
power
supply
X.
4.
Replace
power
supply
X.
QA
Cache
1.8V
Power
Good
Fault
1.
Reseat
the
microprocessor
tray.
2.
(Trained
service
technician
only)
Reseat
the
microprocessors.
3.
Reseat
the
microprocessor
VRMs,
if
present.
4.
(Trained
service
technician
only)
Replace
the
microprocessor
tray.
Chapter
5.
Diagnostics
139
Содержание 88643RU - System x3850 - 8864
Страница 1: ...IBM System x3850 Type 8864 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...IBM System x3850 Type 8864 Problem Determination and Service Guide...
Страница 8: ...vi IBM System x3850 Type 8864 Problem Determination and Service Guide...
Страница 28: ...12 IBM System x3850 Type 8864 Problem Determination and Service Guide...
Страница 38: ...22 IBM System x3850 Type 8864 Problem Determination and Service Guide...
Страница 176: ...160 IBM System x3850 Type 8864 Problem Determination and Service Guide...
Страница 190: ...174 IBM System x3850 Type 8864 Problem Determination and Service Guide...
Страница 191: ......
Страница 192: ...Part Number 31R1885 Printed in USA 1P P N 31R1885...