Symptom
Action
The
amount
of
system
memory
that
is
displayed
is
less
than
the
amount
of
installed
physical
memory.
Note:
If
you
change
the
memory,
you
must
updated
the
memory
configuration
in
the
Configuration/Setup
Utility
program.
1.
Make
sure
that:
v
No
error
LEDs
are
lit
on
the
operator
information
panel
or
on
the
memory
card.
v
Memory
mirroring
does
not
account
for
the
discrepancy.
v
The
memory
modules
are
seated
correctly.
v
You
have
installed
the
correct
type
of
memory.
v
All
banks
of
memory
are
enabled.
The
server
might
have
automatically
disabled
a
memory
bank
when
it
detected
a
problem,
or
a
memory
bank
might
have
been
manually
disabled.
2.
Check
the
POST
error
log
for
error
message
289:
v
If
a
DIMM
was
disabled
by
a
system-management
interrupt
(SMI),
replace
the
DIMM.
v
If
a
DIMM
was
disabled
by
the
user
or
by
POST,
run
the
Configuration/Setup
Utility
program
and
enable
the
DIMM.
3.
Run
memory
diagnostics
(see
“Running
the
on-board
diagnostic
programs”
on
page
111).
4.
Make
sure
there
is
no
memory
mismatch
when
the
server
is
at
the
minimum
memory
configuration
(two
1GB
DIMMs;
see
“Minimum
configuration”
on
page
156).
5.
Add
one
pair
of
DIMMs
at
a
time,
making
sure
the
DIMMs
match
for
each
pair
added.
6.
Add
one
memory
card
at
a
time,
making
sure
the
memory
matches
for
each
card
added.
7.
Reseat
the
following
components:
a.
DIMM
b.
Memory
card
8.
Replace
the
components
listed
in
step
7
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
Chapter
5.
Diagnostics
93
Содержание 88643RU - System x3850 - 8864
Страница 1: ...IBM System x3850 Type 8864 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...IBM System x3850 Type 8864 Problem Determination and Service Guide...
Страница 8: ...vi IBM System x3850 Type 8864 Problem Determination and Service Guide...
Страница 28: ...12 IBM System x3850 Type 8864 Problem Determination and Service Guide...
Страница 38: ...22 IBM System x3850 Type 8864 Problem Determination and Service Guide...
Страница 176: ...160 IBM System x3850 Type 8864 Problem Determination and Service Guide...
Страница 190: ...174 IBM System x3850 Type 8864 Problem Determination and Service Guide...
Страница 191: ......
Страница 192: ...Part Number 31R1885 Printed in USA 1P P N 31R1885...