9.
Install
the
air
baffle
in
the
microprocessor
tray.
10.
Install
the
microprocessor
tray
in
the
server:
a.
Make
sure
that
the
microprocessor-tray
release
latch
is
open;
then,
push
the
microprocessor
tray
into
the
server.
b.
Close
the
tray
levers
and
make
sure
they
are
securely
latched.
c.
Close
the
microprocessor-tray
release
latch.
d.
Reinstall
the
fans
and
memory
cards
in
the
server.
11.
Reinstall
the
top
cover
and
bezel.
12.
Reconnect
external
cables
and
power
cords.
Thermal
grease
The
thermal
grease
must
be
replaced
whenever
the
heat
sink
has
been
removed
from
the
top
of
the
microprocessor
and
is
going
to
be
reused
or
when
debris
is
found
in
the
grease.
To
replace
damaged
or
contaminated
thermal
grease
on
the
microprocessor
and
heat
sink,
complete
the
following
steps:
1.
Place
the
heat
sink
on
a
clean
work
surface.
2.
Remove
the
cleaning
pad
from
its
package
and
unfold
it
completely.
3.
Use
the
cleaning
pad
to
wipe
the
thermal
grease
from
the
bottom
of
the
heat
sink.
Note:
Make
sure
that
all
of
the
thermal
grease
is
removed.
4.
Use
a
clean
area
of
the
cleaning
pad
to
wipe
the
thermal
grease
from
the
microprocessor;
then,
dispose
of
the
cleaning
pad
after
all
of
the
thermal
grease
is
removed.
Microprocessor
0.01 mL of
thermal grease
5.
Use
the
thermal-grease
syringe
to
place
16
uniformly
spaced
dots
of
0.01
mL
each
on
the
top
of
the
microprocessor.
Note:
0.01mL
is
one
tick
mark
on
the
syringe.
If
the
grease
is
properly
applied,
approximately
half
(0.22
mL)
of
the
grease
will
remain
in
the
syringe.
6.
Install
the
heat
sink
onto
the
microprocessor
as
described
in
“Removing
and
installing
a
microprocessor”
on
page
55.
58
IBM
System
x3850
Type
8864:
Problem
Determination
and
Service
Guide
Содержание 88643RU - System x3850 - 8864
Страница 1: ...IBM System x3850 Type 8864 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...IBM System x3850 Type 8864 Problem Determination and Service Guide...
Страница 8: ...vi IBM System x3850 Type 8864 Problem Determination and Service Guide...
Страница 28: ...12 IBM System x3850 Type 8864 Problem Determination and Service Guide...
Страница 38: ...22 IBM System x3850 Type 8864 Problem Determination and Service Guide...
Страница 176: ...160 IBM System x3850 Type 8864 Problem Determination and Service Guide...
Страница 190: ...174 IBM System x3850 Type 8864 Problem Determination and Service Guide...
Страница 191: ......
Страница 192: ...Part Number 31R1885 Printed in USA 1P P N 31R1885...