v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
Chapter
3,
“Parts
listing,
Type
8864,”
on
page
23
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only)”,
that
step
must
be
performed
only
by
a
trained
service
technician.
System-error
log
message
Action
IB
MR
Reg
1.8V
Power
Good
Fault
1.
Reseat
the
microprocessor
tray.
2.
Reseat
the
memory
cards.
3.
(Trained
service
technician
only)
Replace
the
microprocessor
tray.
Invalid
CPU
configuration
Make
sure
that
the
microprocessors
have
been
installed
in
the
correct
order
(see
“Removing
and
installing
a
microprocessor”
on
page
55).
Invalid
Fan
configuration
Replace
any
missing
or
failed
fans.
IP
address
of
default
gateway
modified
from
x.x.x.x
Information
only
IP
address
of
network
interface
modified
from
x.x.x.x
Information
only
IP
subnet
mask
of
network
interface
modified
from
x.x.x.x
Information
only
Loader
Watchdog
Triggered
1.
Reconfigure
the
loader
watchdog
timer
to
be
a
higher
value
(twice
the
normal
operating-system
boot
time).
2.
Install
the
Remote
Supervisor
Adapter
II
SlimLine
device
driver
for
the
operating
system.
3.
Disable
the
loader
watchdog.
4.
Check
the
integrity
of
the
installed
operating
system.
5.
Reinstall
the
operating
system
with
the
applicable
device
drivers.
Machine
check
asserted
-
SPINT,
North
Bridge
Information
only,
Just
an
indication
of
who
reported
the
SPINT
first.
Machine
check
asserted
-
SPINT,
PCI
Bridge
A
Information
only.
Just
an
indication
of
who
reported
the
SPINT
first.
Machine
check
asserted
-
SPINT,
PCI
Bridge
B
Information
only.
Just
an
indication
of
who
reported
the
SPINT
first.
Machine
check
asserted
-
SPINT,
Remote
CheckStop
Information
only.
Just
an
indication
of
who
reported
the
SPINT
first.
Machine
check
asserted
for
Card
or
Link
-
SPINT,
Remote
Node,
Link
1
Information
only.
The
machine
check
was
reported
by
the
node
connected
to
scalability
port
1.
Machine
check
asserted
for
Card
or
Link
-
SPINT,
Remote
Node,
Link
2
Information
only.
The
machine
check
was
reported
by
the
node
connected
to
scalability
port
2.
Machine
check
asserted
for
Card
or
Link
-
SPINT,
Remote
Node,
Link
3
Information
only.
The
machine
check
was
reported
by
the
node
connected
to
scalability
port
3.
Machine
check
asserted
for
Card
or
Link
-
SPINT,
Scalability
1.
Reseat
the
scalability
cables
and
microprocessor
board.
2.
Replace
the
scalability
cables
3.
Replace
the
scalability
cartridge
assembly.
4.
Replace
the
microprocessor
board.
Machine
check
asserted
for
Card
or
Link
-
SPINT,
Quad
Bus
A
1.
Reseat
microprocessor
1
and
2.
2.
Replace
microprocessor
1
or
2.
3.
Replace
the
microprocessor
board.
136
IBM
System
x3850
Type
8864:
Problem
Determination
and
Service
Guide
Содержание 88643RU - System x3850 - 8864
Страница 1: ...IBM System x3850 Type 8864 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...IBM System x3850 Type 8864 Problem Determination and Service Guide...
Страница 8: ...vi IBM System x3850 Type 8864 Problem Determination and Service Guide...
Страница 28: ...12 IBM System x3850 Type 8864 Problem Determination and Service Guide...
Страница 38: ...22 IBM System x3850 Type 8864 Problem Determination and Service Guide...
Страница 176: ...160 IBM System x3850 Type 8864 Problem Determination and Service Guide...
Страница 190: ...174 IBM System x3850 Type 8864 Problem Determination and Service Guide...
Страница 191: ......
Страница 192: ...Part Number 31R1885 Printed in USA 1P P N 31R1885...