v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
Chapter
3,
“Parts
listing,
Type
8864,”
on
page
23
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only)”,
that
step
must
be
performed
only
by
a
trained
service
technician.
System-error
log
message
Action
CPU
IERR
detected,
the
system
has
been
restarted
Information
only;
if
the
message
persists:
1.
(Trained
service
technician
only)
Reseat
the
microprocessors.
2.
Reseat
the
microprocessor
VRMs,
if
present.
3.
(Trained
service
technician
only)
Replace
the
microprocessor.
CPU
IERR,
the
CPU
has
been
disabled
Information
only;
if
the
message
persists:
1.
(Trained
service
technician
only)
Reseat
the
microprocessors.
2.
Reseat
the
microprocessor
VRMs,
if
present.
3.
(Trained
service
technician
only)
Replace
the
microprocessor.
CPU
non-critical
over
temperature
warning
1.
Make
sure
that
the
fans
have
good
airflow
and
are
not
obstructed.
2.
(Trained
service
technician
only)
Reseat
the
microprocessor
heat
sink.
CPU
non-recoverable
over
temperature
fault
1.
Make
sure
that
the
fans
have
good
airflow
and
are
not
obstructed.
2.
(Trained
service
technician
only)
Reseat
the
microprocessor
heat
sink.
CPU
mismatch:
CPU
unsupported
by
VRM.
CPU
nn,
where
nn
is
the
CPU
number.
Replace
the
10.1
VRM
with
a
10.2
VRM.
CPU
removal
detected
Informational
only;
if
the
message
persists:
1.
(Trained
service
technician
only)
Reseat
the
microprocessors.
2.
Reseat
the
microprocessor
VRMs,
if
present.
CPU
X
Over
Temperature
1.
Check
all
fans
and
remove
any
obstacles
from
the
path
of
the
airflow.
2.
Make
sure
that
the
room
temperature
is
within
the
recommended
range.
3.
Make
sure
that
the
microprocessor
heat
sinks
are
correctly
seated.
Ethernet
Data
Rate
modified
from
<value1>
to
<value2>
by
user
<USERID>
Information
only
Ethernet
Duplex
setting
modified
from
<value1>
to
<value1>
by
user
<USERID>
Information
only
Ethernet
interface
<value>
by
user
<USERID>
Information
only
Ethernet
locally
administered
MAC
address
modified
from
x:x:x:x:x:x
Information
only
Ethernet
MTU
setting
modified
from
x
to
y
by
user
<USERID>
Information
only
Fan
X
Failure
(X
of
1-8)
1.
Make
sure
that
nothing
is
blocking
the
fan.
2.
Check
the
physical
connection
and
make
sure
that
the
fan
is
correctly
seated.
3.
Replace
fan
X.
134
IBM
System
x3850
Type
8864:
Problem
Determination
and
Service
Guide
Содержание 88643RU - System x3850 - 8864
Страница 1: ...IBM System x3850 Type 8864 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...IBM System x3850 Type 8864 Problem Determination and Service Guide...
Страница 8: ...vi IBM System x3850 Type 8864 Problem Determination and Service Guide...
Страница 28: ...12 IBM System x3850 Type 8864 Problem Determination and Service Guide...
Страница 38: ...22 IBM System x3850 Type 8864 Problem Determination and Service Guide...
Страница 176: ...160 IBM System x3850 Type 8864 Problem Determination and Service Guide...
Страница 190: ...174 IBM System x3850 Type 8864 Problem Determination and Service Guide...
Страница 191: ......
Страница 192: ...Part Number 31R1885 Printed in USA 1P P N 31R1885...