v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
Chapter
3,
“Parts
listing,
Type
8864,”
on
page
23
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only)”,
that
step
must
be
performed
only
by
a
trained
service
technician.
Error
code
Description
Action
201-xxx-CBN
Failed
Memory
Test:
See
“Memory
module”
on
page
38.
v
C
=
memory
card
[1-4]
v
B
=
physical
bank
[1-2]
Note:
Bank
1
=
DIMMs
1
and
3;
Bank
2
=
DIMMs
2
and
4
v
N
=
failing
DIMM
[1-4]
1.
Reseat
the
following
components:
a.
DIMM
N
b.
Memory
card
C
2.
Replace
the
components
listed
in
step
1
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
Note:
N
=
9
indicates
both
DIMMs
in
physical
bank
B
and
memory
card
C.
202-xxx-0nn
Failed
system
cache
test,
where
nn=APIC
ID.
APIC
ID
(physical
mode)
Microprocessor
00,
01,
02,
03
1
04,
05,
06,
07
2
10,
11,
12,
13
3
14,
15,
16,
17
4
APIC
ID
(logical
mode)
Microprocessor
00,
01,
02,
03
1
24,
25,
26,
27
2
10,
11,
12,
13
3
34,
35,
36,
37
4
1.
Reseat
the
following
components:
a.
(Trained
service
technician
only)
Microprocessor
nn
b.
Microprocessor
tray
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
a.
(Trained
service
technician
only)
Microprocessor
nn
b.
(Trained
service
technician
only)
Microprocessor
tray
204-198-000
Test
aborted.
1.
Run
the
Quick
Memory
Test
Diagnostic
All
Banks
(see
“Running
the
on-board
diagnostic
programs”
on
page
111).
2.
Update
the
BIOS
code
(see
“Updating
the
firmware”
on
page
13).
3.
Look
in
the
test
log
(see
“Viewing
the
test
log”
on
page
112)
and
correct
any
other
errors.
204-210-000
Test
failed.
1.
Run
the
Quick
Memory
Test
Diagnostic
All
Banks
(see
“Running
the
on-board
diagnostic
programs”
on
page
111).
2.
Update
the
BIOS
code
(see
“Updating
the
firmware”
on
page
13).
3.
Look
in
the
test
log
(see
“Viewing
the
test
log”
on
page
112)
and
correct
any
other
errors.
Chapter
5.
Diagnostics
127
Содержание 88643RU - System x3850 - 8864
Страница 1: ...IBM System x3850 Type 8864 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...IBM System x3850 Type 8864 Problem Determination and Service Guide...
Страница 8: ...vi IBM System x3850 Type 8864 Problem Determination and Service Guide...
Страница 28: ...12 IBM System x3850 Type 8864 Problem Determination and Service Guide...
Страница 38: ...22 IBM System x3850 Type 8864 Problem Determination and Service Guide...
Страница 176: ...160 IBM System x3850 Type 8864 Problem Determination and Service Guide...
Страница 190: ...174 IBM System x3850 Type 8864 Problem Determination and Service Guide...
Страница 191: ......
Страница 192: ...Part Number 31R1885 Printed in USA 1P P N 31R1885...