Configuring the Modem
The CPSW module supports the use of dial-in modems with the following requirements:
The modem must be 100% Hayes-compatible
Any valid baud rate (300, 1200, 2400, 9600, 19200) may be used. 9600 is recommended.
The modem must be set to Dumb/Auto Answer mode.
To configure a modem, enter the following commands from the console to which the modem is attached:
1. Type
at&F
and press Enter (to restore the factory default settings).
2. Type
at&dð
and press Enter (to ignore changes in DTR status) If you have enabled automatic modem
hangup with the SET TERMINAL HANGUP ENABLE command and want to keep this setting, enter
at&d2
and press Enter. This sets the DTR parameter so that hangup remains enabled when DTR
switches from ON to OFF.
3. Type
atsð=1
and press Enter (to auto-answer on the first ring).
4. Type
atsð?
and press Enter (to verify the auto-answer if 001 is returned).
5. Type
atq1
and press Enter (to ignore the result codes).
6. Type
at&W
and press Enter (to save the configuration changes).
7. Type
at&Y
and press Enter (to define the configuration as the new default).
8. Set the modem to Dumb mode (with command recognition disabled) by following the instructions in
the modem's user guide.
40
IBM 8265: Installation Guide
Содержание 8265 Nways ATM Switch
Страница 1: ...8265 Nways ATM Switch IBM Installation Guide SA33 0441 02...
Страница 2: ......
Страница 3: ...8265 Nways ATM Switch IBM Installation Guide SA33 0441 02...
Страница 8: ...vi IBM 8265 Installation Guide...
Страница 10: ...viii IBM 8265 Installation Guide...
Страница 12: ...x IBM 8265 Installation Guide...
Страница 14: ...xii IBM 8265 Installation Guide...
Страница 32: ...18 IBM 8265 Installation Guide...
Страница 52: ...38 IBM 8265 Installation Guide...
Страница 68: ...54 IBM 8265 Installation Guide...
Страница 88: ...Models 17S Serial Number Located on the 8265 chassis label 74 IBM 8265 Installation Guide...
Страница 98: ......
Страница 101: ......
Страница 102: ...IBM SA33 441 2...