Additional Components
The following components are required to operate the 8265 (these components are ordered separately
from the 8265 chassis):
Power supplies (at least two are required), either:
– 415 W AC (Feature Code 8027), or
– 295 W DC –48 V (Feature Code 8026 or 8028)
You cannot mix AC and DC power supplies.
Control Point and Switch (CPSW) module(s), either:
– Feature Code 6501 (standard model), or
– Feature Code 6502 (enhanced model, also referred to as CPSW2), with integrated power control.
One Control Point and Switch module is required for normal operation. A second module made be
installed for redundancy purposes, provided both modules are of the same type.
Controller module(s) (Feature Code 8000)
Only required when the standard CPSW module (Feature Code 6501) is used. May be installed in
conjuction with CPSW2 module (Feature Code 6502) if you prefer power control to be handled by a
Controller module instead of the CPSW2 module.
One Controller module is required for normal operation. A second module made be installed for
redundancy purposes.
A PCMCIA card containing the Control Point and Switch microcode. This card must be inserted in the
Control Point and Switch module before the module is inserted in the 8265. The following cards are
available:
– Base microcode with UNI and IISP functions (Feature Code 6545)
– Enhanced microcode with UNI, IISP, and PNNI functions (Feature Code 6546)
Media modules (at least one is required).
Check that these components are available before commencing the installation of the 8265.
The following components are optional (and are ordered separately from the 8265 chassis):
Rack Mount Kit, Part Number 25H1834.
Cable Management Tray, Part Number 13J8751.
16 MB Memory upgrade (Feature Code 6516) for the standard Control Point and Switch modules
(Feature Code 6501).
Note: This memory upgrade is required when running the enhanced version of microcode.
Documentation CD-ROM (automatically included when PCMCIA card ordered), Feature Code 6508.
Unpacking Components
Unpack components only when you are ready to install them. Instructions and guidelines for unpacking
components are given in each section later in the book.
6
IBM 8265: Installation Guide
Содержание 8265 Nways ATM Switch
Страница 1: ...8265 Nways ATM Switch IBM Installation Guide SA33 0441 02...
Страница 2: ......
Страница 3: ...8265 Nways ATM Switch IBM Installation Guide SA33 0441 02...
Страница 8: ...vi IBM 8265 Installation Guide...
Страница 10: ...viii IBM 8265 Installation Guide...
Страница 12: ...x IBM 8265 Installation Guide...
Страница 14: ...xii IBM 8265 Installation Guide...
Страница 32: ...18 IBM 8265 Installation Guide...
Страница 52: ...38 IBM 8265 Installation Guide...
Страница 68: ...54 IBM 8265 Installation Guide...
Страница 88: ...Models 17S Serial Number Located on the 8265 chassis label 74 IBM 8265 Installation Guide...
Страница 98: ......
Страница 101: ......
Страница 102: ...IBM SA33 441 2...