Pre-installation Guidelines
Before installing the cable management tray in a rack, determine which cable management tray rack
mount position is best for you by examining the following:
Location in the rack where the switch will be installed (refer to “Pre-installation Guidelines” on
page 13).
Depth of the rack in to which the switch will be installed.
Space required for ventilation. A minimum of 15 cm (6 in.) is required between the rear of the 8265
and the nearest wall or vertical surface.
Room required for module cables to bend.
Proximity of other devices in the rack and their installation or environmental requirements.
Figure 2 shows cable management tray rack mount positions.
Flush Mount
5/8" (1.6 cm) Recess
2 1/8" (5.4 cm) Recess
2 3/4" (7.0 cm) Recess
Figure 2. Cable Management Tray Rack Mount Positions
Table 2 provides cable management tray rack settings.
Table 2. Rack Mount Settings for Cable Management Tray
Setting
Description
Flush mount
Mounts the tray flush with the front of the rack.
5/8-inch (1.6 cm) recess
Recesses the tray 5/8-inch (1.6 cm) from the front of the rack.
2 1/8-inch (5.4 cm) recess
Recesses the tray 2 1/8-inch (5.4 cm) from the front of the rack.
2 3/4-inch (7.0 cm) recess
Recesses the tray 2 3/4-inch (7.0 cm) from the front of the rack.
Select any rack position that is at least 28 inches (approximately 71 cm) from the top of the rack or the
next higher unit in the rack.
Be sure to select a rack position that leaves you enough room to install the cable management tray below
the installed switch.
Chapter 3. Installing the Chassis
9
Содержание 8265 Nways ATM Switch
Страница 1: ...8265 Nways ATM Switch IBM Installation Guide SA33 0441 02...
Страница 2: ......
Страница 3: ...8265 Nways ATM Switch IBM Installation Guide SA33 0441 02...
Страница 8: ...vi IBM 8265 Installation Guide...
Страница 10: ...viii IBM 8265 Installation Guide...
Страница 12: ...x IBM 8265 Installation Guide...
Страница 14: ...xii IBM 8265 Installation Guide...
Страница 32: ...18 IBM 8265 Installation Guide...
Страница 52: ...38 IBM 8265 Installation Guide...
Страница 68: ...54 IBM 8265 Installation Guide...
Страница 88: ...Models 17S Serial Number Located on the 8265 chassis label 74 IBM 8265 Installation Guide...
Страница 98: ......
Страница 101: ......
Страница 102: ...IBM SA33 441 2...