v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
BMC
log
message
Sensor
number
Sensor
type
Action
ABR
status
8F
0F
Information
only
CPU
1
status
Assertion
01
(Thermal
trip)
90
07
Information
only;
if
the
message
remains:
1.
Make
sure
that
the
fans
have
good
airflow
and
are
not
obstructed.
2.
(Trained
service
technician
only)
Reseat
the
microprocessor.
3.
(Trained
service
technician
only)
Replace
the
microprocessor.
CPU
1
status
Assertion
05
(Configuration
error)
90
07
(Trained
service
technician
only)
Make
sure
that
the
microprocessor
is
installed
correctly.
CPU
1
status
Assertion
07
(Processor
presence
detected)
or
0A
(Processor
automatically
throttled)
90
07
Information
only
CPU
1
status
Assertion
08
(Processor
disabled)
90
07
1.
Check
the
DIMM
error
LEDs
on
the
system
board.
2.
(Trained
service
technician
only)
Reseat
the
microprocessor.
3.
(Trained
service
technician
only)
Reseat
the
microprocessor.
4.
(Trained
service
technician
only)
Replace
the
microprocessor.
CPU
2
status
Assertion
01
(Thermal
trip)
91
07
Information
only;
if
the
message
remains:
1.
Make
sure
that
the
fans
have
good
airflow
and
are
not
obstructed.
2.
(Trained
service
technician
only)
Reseat
the
microprocessor.
3.
(Trained
service
technician
only)
Replace
the
microprocessor.
CPU
2
status
Assertion
05
(Configuration
error)
91
07
(Trained
service
technician
only)
Make
sure
that
the
microprocessor
is
installed
correctly.
CPU
2
status
Assertion
07
(Processor
presence
detected)
or
0A
(Processor
automatically
throttled)
91
07
Information
only
CPU
2
status
Assertion
08
(Processor
disabled)
91
07
1.
Check
the
DIMM
error
LEDs
on
the
microprocessor.
2.
(Trained
service
technician
only)
Reseat
the
microprocessor.
3.
(Trained
service
technician
only)
Replace
the
microprocessor.
CPU
1
temperature
98
01
1.
Check
all
fans
and
remove
any
obstacles
from
the
path
of
the
airflow.
2.
Make
sure
that
the
room
temperature
is
within
the
recommended
range.
Chapter
3.
Diagnostics
83
Содержание 7985
Страница 1: ...IBM System x3655 Type 7985 and 7943 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...IBM System x3655 Type 7985 and 7943 Problem Determination and Service Guide...
Страница 8: ...vi IBM System x3655 Type 7985 and 7943 Problem Determination and Service Guide...
Страница 18: ...xvi IBM System x3655 Type 7985 and 7943 Problem Determination and Service Guide...
Страница 36: ...18 IBM System x3655 Type 7985 and 7943 Problem Determination and Service Guide...
Страница 110: ...92 IBM System x3655 Type 7985 and 7943 Problem Determination and Service Guide...
Страница 112: ...View 1...
Страница 159: ...Battery Chapter 5 Removing and replacing server components 141...
Страница 202: ...184 IBM System x3655 Type 7985 and 7943 Problem Determination and Service Guide...
Страница 212: ...194 IBM System x3655 Type 7985 and 7943 Problem Determination and Service Guide...
Страница 217: ......
Страница 218: ...Part Number 42D2167 Printed in USA 1P P N 42D2167...