Error
code
Description
Action
166-198-000
System
Management:
Aborted
1.
Run
the
diagnostic
test
again.
2.
Correct
other
error
conditions
(including
failed
system
management
tests
and
items
logged
in
the
BMC
error
log
and
the
system
event/error
log)
and
retry
the
test.
3.
Disconnect
all
server
and
option
power
cords
from
the
server,
wait
30
seconds,
reconnect
the
power
cords,
and
retry
the
test.
4.
Replace
the
Remote
Supervisor
Adapter
II
SlimLine,
if
installed.
5.
(Trained
service
technician
only)
Replace
the
system
board.
166-201-000
BMC
indicates
I2C
errors
on
bus
0.
(Trained
service
technician
only)
Replace
the
system
board.
166-201-001
BMC
indicates
I2C
errors
on
bus
1.
1.
(Trained
service
technician
only)
Reseat
the
microprocessor.
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
(Trained
service
technician
only)
Microprocessor
b.
(Trained
service
technician
only)
System
board
166-201-002
BMC
indicates
I2C
errors
on
bus
2.
(Trained
service
technician
only)
Replace
the
system
board.
166-201-003
BMC
indicates
I2C
errors
on
bus
3.
(Trained
service
technician
only)
Replace
the
system
board.
166-201-004
BMC
indicates
I2C
errors
on
bus
4.
(Trained
service
technician
only)
Replace
the
system
board.
166-201-005
BMC
indicates
I2C
errors
on
bus
5.
(Trained
service
technician
only)
Replace
the
system
board.
166-201-006
BMC
indicates
I2C
errors
on
bus
6.
(Trained
service
technician
only)
Replace
the
system
board.
166-201-007
BMC
indicates
I2C
errors
on
bus
7.
1.
(Trained
service
technician
only)
Reseat
the
microprocessor.
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
(Trained
service
technician
only)
Microprocessor
b.
(Trained
service
technician
only)
System
board
Chapter
3.
Diagnostics
61
Содержание 7985
Страница 1: ...IBM System x3655 Type 7985 and 7943 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...IBM System x3655 Type 7985 and 7943 Problem Determination and Service Guide...
Страница 8: ...vi IBM System x3655 Type 7985 and 7943 Problem Determination and Service Guide...
Страница 18: ...xvi IBM System x3655 Type 7985 and 7943 Problem Determination and Service Guide...
Страница 36: ...18 IBM System x3655 Type 7985 and 7943 Problem Determination and Service Guide...
Страница 110: ...92 IBM System x3655 Type 7985 and 7943 Problem Determination and Service Guide...
Страница 112: ...View 1...
Страница 159: ...Battery Chapter 5 Removing and replacing server components 141...
Страница 202: ...184 IBM System x3655 Type 7985 and 7943 Problem Determination and Service Guide...
Страница 212: ...194 IBM System x3655 Type 7985 and 7943 Problem Determination and Service Guide...
Страница 217: ......
Страница 218: ...Part Number 42D2167 Printed in USA 1P P N 42D2167...