A.0 Appendix A. Line Cord Requirements
To avoid electrical shock, a line cord with a grounded attachment plug is provided. Use only properly grounded outlets.
Line Cords used in the United States and Canada are listed by Underwriter's Laboratories (UL**) and certified by the Canadian Standards
Association (CSA**). These line cords consist of:
Electrical line cords, type SVT or SJT
Attachment plugs complying with National Electrical Manufacturers Association (NEMA) 5-15P.
For 115 V operation, use a UL-listed cable set consisting of a minimum 18 AWG, type SVT or SJT 3 conductor cable that is a
maximum of 15 feet in length, and a parallel blade, grounding-type attachment plug rated at 15 A, 125 V.
For 230 V operation in the United States, use a UL-listed cable set consisting of a minimum 18 AWG, type SVT or SJT 3 conductor
cable that is a maximum of 15 feet in length, and a tandem blade, grounding-type attachment plug rated at 15 A, 250 B.
Appliance couplets complying with International Electrotechnical Commission (IEC) Standard 320, Sheet C13
Line cords used in other countries consist of:
Electrical line cord, type HD21
Attachment plugs approved by the appropriate testing organization for the specific countries where they are used
For units set at 230 V (outside of the United States), use a cable set consisting of a minimum 18 AWG cable and a grounding-type
attachment plug rated at 15A, 250 V. The cable set should have the appropriate safety approvals for the country in which the
equipment will be installed and should be marked "HAR".
Table A-1 lists the line cord part number, the country where the line cord can be used, and an index number to be matched with the
receptacle illustrations shown in Figure A-1. Contact your IBM representative if your 7131 Storage Tower disk drive line cord does not
match this information.
+------------------------------------------------------------------------+
¦ Table A-1. Line Cord and Country Matrix ¦
+------------------------------------------------------------------------¦
¦ Feature¦ Line Cord ¦ ¦ ¦
¦ ¦ ¦ ¦ ¦
¦ Code ¦ Part Number ¦ Country ¦ Index ¦
+--------+--------------+--------------------------------------+---------¦
¦ 9800 ¦ 6952300 ¦ 2.7M, 9-Foot Line Cord, United ¦ 1 ¦
¦ ¦ ¦ States and Canada: 110 V to 127 V 60 ¦ ¦
¦ ¦ ¦ HZ ¦ ¦
¦ ¦ ¦ ¦ ¦
¦ ¦ ¦ Antilles, Balarrus, Barbados, ¦ ¦
¦ ¦ ¦ Bermuda, Bolivia, Brazil, Canada, ¦ ¦
¦ ¦ ¦ Cayman Islands, Colombia, Costa ¦ ¦
¦ ¦ ¦ Rica, Dominican Republic, Ecuador, ¦ ¦
¦ ¦ ¦ El Salvador, Guatemala, Guyana, ¦ ¦
¦ ¦ ¦ Haiti, Honduras, Jamaica, Japan, ¦ ¦
¦ ¦ ¦ Korea (South), Liberia, Mexico, ¦ ¦
¦ ¦ ¦ Netherlands, Nicaragua, Panama, ¦ ¦
¦ ¦ ¦ Peru, Philippines, Saudi Arabia, ¦ ¦
¦ ¦ ¦ Suriname, Taiwan, Trinidad (West ¦ ¦
¦ ¦ ¦ Indies), United States, 110 V ¦ ¦
+--------+--------------+--------------------------------------+---------¦
¦ 9820 ¦ 13F9979 ¦ 2.9M, 9-Foot Line Cord, France, 220 ¦ 2 ¦
¦ ¦ ¦ V to 240 V 50 HZ ¦ ¦
¦ ¦ ¦ ¦ ¦
¦ ¦ ¦ Afghanistan, Algeria, Andorra, ¦ ¦
¦ ¦ ¦ Angola, Austria, Belgium, Benin, ¦ ¦
¦ ¦ ¦ Bulgaria, Burkina Faso, Burundi, ¦ ¦
¦ ¦ ¦ Cameroon, Central African Rep, Chad, ¦ ¦
¦ ¦ ¦ Dzech Republic, Egypt, Finland, ¦ ¦
¦ ¦ ¦ France, French Guiana, Germany, ¦ ¦
¦ ¦ ¦ Greece, Guinea, Hungary, Iceland, ¦ ¦
¦ ¦ ¦ Indonesia, Iran, Ivory Coast, ¦ ¦
¦ ¦ ¦ Jordan, Lebanon, Luxembourg, Macau, ¦ ¦
¦ ¦ ¦ Malagasy, Mali, Martinique, ¦ ¦
¦ ¦ ¦ Mauritania, Mauritanian, Monaco, ¦ ¦
¦ ¦ ¦ Morocco, Mozambique, Netherlands, ¦ ¦
¦ ¦ ¦ New Caledonia, Niger, Norway, ¦ ¦
¦ ¦ ¦ Poland, Portugal, Romania, Senegal, ¦ ¦
¦ ¦ ¦ Slovakia, Spain, Sudan, Sweden, ¦ ¦
¦ ¦ ¦ Syria, Togo, Tunisia, Turkey, former ¦ ¦
¦ ¦ ¦ USSR, Vietnam, former Yugoslavia, ¦ ¦
¦ ¦ ¦ Zaire, Zimbabwe ¦ ¦
+--------+--------------+--------------------------------------+---------¦
¦ 9821 ¦ 13F9997 ¦ 2.7M, 9-Foot Line Cord, Denmark, 220 ¦ 3 ¦
¦ ¦ ¦ V to 250 V 60 HZ ¦ ¦
7131-105 User's Guide
Appendix A. Line Cord Requirements
¦ Copyright IBM Corp. 1995, 1996
A.0 - 1