FRU Exchange
Chapter 4. 3745 FRU Exchange
This chapter is to be used to exchange a defined FRU. Use all section from the begining to the end, to
determine:
1. Where the FRU is physically located
2. How to properly exchange FRUs
3. How to test the machine
4. What else must be done before returning the machine to the customer.
Exchange Precautions
1. Most of the 3745 FRUs can be exchanged in concurrent maintenance. Thus, it is very important that
these procedures be followed when replacing any FRU in the machine.
2. The control panel has voltage present even with the machine Powered OFF.
3. Ensure that the 3745 is powered OFF before replacing any FRUs, except for hot-pluggable FRUs
(LIC,MUX) and the separated power-controlled FRUs (FDD and HDD).
4. Before starting the FRU exchange, ensure that the involved area has been disabled by the cus-
tomer.
5. The 3745 Communication Controller contains cards that are sensitive to electrostatic discharge (ESD).
Use the ESD kit and store all cards in their protective packaging when you are not actually exchanging
them.
6. Procedures for exchanging FRUs are listed on the next pages. Use the list in alphabetical order.
7. After the 3745 FRU exchange, go to “Action to Take After a Diagnostic Run or an FRU Exchange” on
page 4-99.
Attention
Do not disassemble or attempt to remove FRUs from the 3745 until you have read the Safety Infor-
mation manual, GA33-0400.
Very important
Ensure that the required area has been disabled
before any FRU exchange
if not, go to start page and follow the appropriate procedure.
Copyright IBM Corp. 1989, 1997
4-1
Содержание 3745 130
Страница 2: ......
Страница 10: ...viii 3745 Models 130 to 17A MIP ...
Страница 16: ...xiv 3745 Models 130 to 17A MIP ...
Страница 23: ...Safety Figure 0 2 Ground Wire Connection on Controller Expansion Safety xxi ...
Страница 25: ...Safety Figure 0 4 Ground Wire Connection Between Controller Expansions at Less than Six Meters Safety xxiii ...
Страница 36: ...Safety Figure 0 12 Schutzleiteranschluß an der Erweiterung der Steuereinheit xxxiv 3745 Models 130 to 17A MIP ...
Страница 37: ...Safety Figure 0 13 Schutzleiteranschluß zwischen angeschlossenen Erweiterungen der Steuereinheit Safety xxxv ...
Страница 46: ...Safety xliv 3745 Models 130 to 17A MIP ...
Страница 47: ...Safety Safety xlv ...
Страница 48: ...Safety xlvi 3745 Models 130 to 17A MIP ...
Страница 49: ...Safety Safety xlvii ...
Страница 50: ...Safety xlviii 3745 Models 130 to 17A MIP ...
Страница 51: ...Safety Safety xlix ...
Страница 52: ...Safety l 3745 Models 130 to 17A MIP ...
Страница 53: ...Safety Safety li ...
Страница 54: ...Safety lii 3745 Models 130 to 17A MIP ...
Страница 55: ...Safety Safety liii ...
Страница 56: ...Safety liv 3745 Models 130 to 17A MIP ...
Страница 57: ...Safety Safety lv ...
Страница 58: ...Safety lvi 3745 Models 130 to 17A MIP ...
Страница 60: ...Safety Figure 0 22 3745 Label and Power Rating Plate Locations Front lviii 3745 Models 130 to 17A MIP ...
Страница 66: ...Safety lxiv 3745 Models 130 to 17A MIP ...
Страница 68: ...Preface lxvi 3745 Models 130 to 17A MIP ...
Страница 70: ...Amendments lxviii 3745 Models 130 to 17A MIP ...
Страница 154: ...3745 MAPs 1 84 3745 Models 130 to 17A MIP ...
Страница 200: ...Service Processor MAPs 2 46 3745 Models 130 to 17A MIP ...
Страница 226: ...Diagnostics 3 26 3745 Models 130 to 17A MIP ...
Страница 253: ...FRU Exchange Location 01S Figure 4 31 3745 EPO Chapter 4 3745 FRU Exchange 4 27 ...
Страница 332: ...CE leaving procedure 4 106 3745 Models 130 to 17A MIP ...
Страница 338: ...Maintenance Aids A 6 3745 Models 130 to 17A MIP ...
Страница 354: ...Abbreviation X 6 3745 Models 130 to 17A MIP ...
Страница 359: ......
Страница 360: ...IBM Part Number 03F5017 Printed in Denmark by IBM Danmark A S ð3F5ð17 SY33 2ð7ð ð9 ...
Страница 361: ...Spine information IBM Models 130 to 17A IBM 3745 Communication Controller Maintenance Information Procedures ...