3745 MAPs
MAP 3220: Undefined Panel Message
Symptom Explanation
Conditions That Could Cause This Symptom
The message on the control panel
is undefined
Loose cables/cards
PCC card failing
Control panel failing
MPC card failing
Microcode update
001
You may have loose cables and/or cards.
If the nature of the fault does not allow control
panel actions, exchange the FRU group 37. Go to
page “3745 FRU Group Table” on page 1-49.
– Power the 3745 OFF as follows:
Put the power control in local mode:
– Using Power Control, scroll till the
value is 3.
– Press Validate.
Press Power Off.
– Switch the CB1 OFF.
– Attention: Use the ESD kit and procedures.
– Refer to Figure 4-9 on page 4-11.
– Carefully check and reseat any loose cables or
cards (especially the MPC, PCC, and MSC).
– Switch the CB1 ON.
Are Power Control and Service Mode indica-
tors displayed on the control panel?
Yes No
002
The initial power checkouts on the PLC card
did not complete successfully.
– Exchange the FRU group 37. Go to “3745
FRU Group Table” on page 1-49.
003
– Press Function on the control panel until the
MOSS IML function 1 is displayed.
– Press Validate.
– Press Power On Reset.
– When the IML is complete, retry the operation
that displayed the unexpected hex display code.
Is the unexpected hex display code problem
resolved?
Yes No
004
Referring to “How to Run the Control Panel
Test” on page 3-8, run the diagnostic. If an
FRU group is called, go to “3745 FRU
Group Table” on page 1-49.
(Step 004 continues)
004 (continued)
– If no errors are detected, consult the
Support Center for any microcode update
which may not be reflected in the MIP.
Have you received more information
from support?
Yes No
005
– Exchange the FRU group 22. Go to
“3745 FRU Group Table” on
page 1-49.
006
– Take action as directed.
Is the problem solved?
Yes No
007
– Exchange the FRU group 22. Go
to “3745 FRU Group Table” on
page 1-49.
008
– In the CE Leaving Procedure you will be
instructed to set the time of day clock,
and set any required scheduled power
ON time.
Go to page “CE Leaving Procedure” on
page 4-102.
009
Did the unexpected hex code occur while you
were using the MIP for another reason?
Yes No
010
Go to Step 008.
011
Restart with Chapter 1, “START: How to Begin
Troubleshooting” on page 1-1.
Chapter 2. Map for FRU Isolation
2-5
Содержание 3745 130
Страница 2: ......
Страница 10: ...viii 3745 Models 130 to 17A MIP ...
Страница 16: ...xiv 3745 Models 130 to 17A MIP ...
Страница 23: ...Safety Figure 0 2 Ground Wire Connection on Controller Expansion Safety xxi ...
Страница 25: ...Safety Figure 0 4 Ground Wire Connection Between Controller Expansions at Less than Six Meters Safety xxiii ...
Страница 36: ...Safety Figure 0 12 Schutzleiteranschluß an der Erweiterung der Steuereinheit xxxiv 3745 Models 130 to 17A MIP ...
Страница 37: ...Safety Figure 0 13 Schutzleiteranschluß zwischen angeschlossenen Erweiterungen der Steuereinheit Safety xxxv ...
Страница 46: ...Safety xliv 3745 Models 130 to 17A MIP ...
Страница 47: ...Safety Safety xlv ...
Страница 48: ...Safety xlvi 3745 Models 130 to 17A MIP ...
Страница 49: ...Safety Safety xlvii ...
Страница 50: ...Safety xlviii 3745 Models 130 to 17A MIP ...
Страница 51: ...Safety Safety xlix ...
Страница 52: ...Safety l 3745 Models 130 to 17A MIP ...
Страница 53: ...Safety Safety li ...
Страница 54: ...Safety lii 3745 Models 130 to 17A MIP ...
Страница 55: ...Safety Safety liii ...
Страница 56: ...Safety liv 3745 Models 130 to 17A MIP ...
Страница 57: ...Safety Safety lv ...
Страница 58: ...Safety lvi 3745 Models 130 to 17A MIP ...
Страница 60: ...Safety Figure 0 22 3745 Label and Power Rating Plate Locations Front lviii 3745 Models 130 to 17A MIP ...
Страница 66: ...Safety lxiv 3745 Models 130 to 17A MIP ...
Страница 68: ...Preface lxvi 3745 Models 130 to 17A MIP ...
Страница 70: ...Amendments lxviii 3745 Models 130 to 17A MIP ...
Страница 154: ...3745 MAPs 1 84 3745 Models 130 to 17A MIP ...
Страница 200: ...Service Processor MAPs 2 46 3745 Models 130 to 17A MIP ...
Страница 226: ...Diagnostics 3 26 3745 Models 130 to 17A MIP ...
Страница 253: ...FRU Exchange Location 01S Figure 4 31 3745 EPO Chapter 4 3745 FRU Exchange 4 27 ...
Страница 332: ...CE leaving procedure 4 106 3745 Models 130 to 17A MIP ...
Страница 338: ...Maintenance Aids A 6 3745 Models 130 to 17A MIP ...
Страница 354: ...Abbreviation X 6 3745 Models 130 to 17A MIP ...
Страница 359: ......
Страница 360: ...IBM Part Number 03F5017 Printed in Denmark by IBM Danmark A S ð3F5ð17 SY33 2ð7ð ð9 ...
Страница 361: ...Spine information IBM Models 130 to 17A IBM 3745 Communication Controller Maintenance Information Procedures ...