3745 FRU Exchange Procedure
LIC Exchange Procedure
Removal Procedure:
Since the LIC is hot-
pluggable, there is no need to power OFF.
1. For physical locations, refer to Figure 4-54,
Figure 4-56, and to Figure 4-57 on
page 4-45.
2. Open the rear door.
3. Remove the line cables from the
PTT/Common carrier wall socket if you deal
with LIC 5 or 6.
4. Remove the line cables from the LIC. Note
their positions.
5. If you are working with LIC 5 or 6, check if the
LIC configuration is available.If it is not, use
the PKD (Refer to the
Connection and Inte-
gration Guide, SA33-0141).
6. Unfasten the thumb screw holding the LIC
cassette to the board.
7. Remove the LIC cassette.
Figure
4-54. Location of the LIC Boards
Line
Speed Switch
W
X
Y
BPS
19200
9600
(V24)
BPS
56000
(V35)
Figure 4-55. LIC 6
Installation Procedure
1. If you are working with a LIC type 6 (refer to
Figure 4-55), note the position of the line
speed switch, then set the line speed switch
of the new LIC accordingly.
2. Install the new LIC cassette.
3. Fasten the thumb screw holding the LIC cas-
sette to the board. Finger strength is enough.
Do not use tools.
4. If a LIC 5 or 6 has been installed, configura-
tion must be done with the PKD (refer to the
Connection and Integration Guide,
SA33-0141).
5. Replace the line cables in their proper posi-
tions on the LIC.
6. Reconnect the line cable(s) to the
PTT/Common carrier wall socket if you are
working with LIC 5 or 6.
7. Close the rear door.
8. Referring to Chapter 3, “How to Run 3745
Diagnostics” on page 3-1, run the same diag-
nostic that you ran before you exchanged the
FRU. Go to “Action to Take After a Diag-
4-44
3745 Models 130 to 17A: MIP
Содержание 3745 130
Страница 2: ......
Страница 10: ...viii 3745 Models 130 to 17A MIP ...
Страница 16: ...xiv 3745 Models 130 to 17A MIP ...
Страница 23: ...Safety Figure 0 2 Ground Wire Connection on Controller Expansion Safety xxi ...
Страница 25: ...Safety Figure 0 4 Ground Wire Connection Between Controller Expansions at Less than Six Meters Safety xxiii ...
Страница 36: ...Safety Figure 0 12 Schutzleiteranschluß an der Erweiterung der Steuereinheit xxxiv 3745 Models 130 to 17A MIP ...
Страница 37: ...Safety Figure 0 13 Schutzleiteranschluß zwischen angeschlossenen Erweiterungen der Steuereinheit Safety xxxv ...
Страница 46: ...Safety xliv 3745 Models 130 to 17A MIP ...
Страница 47: ...Safety Safety xlv ...
Страница 48: ...Safety xlvi 3745 Models 130 to 17A MIP ...
Страница 49: ...Safety Safety xlvii ...
Страница 50: ...Safety xlviii 3745 Models 130 to 17A MIP ...
Страница 51: ...Safety Safety xlix ...
Страница 52: ...Safety l 3745 Models 130 to 17A MIP ...
Страница 53: ...Safety Safety li ...
Страница 54: ...Safety lii 3745 Models 130 to 17A MIP ...
Страница 55: ...Safety Safety liii ...
Страница 56: ...Safety liv 3745 Models 130 to 17A MIP ...
Страница 57: ...Safety Safety lv ...
Страница 58: ...Safety lvi 3745 Models 130 to 17A MIP ...
Страница 60: ...Safety Figure 0 22 3745 Label and Power Rating Plate Locations Front lviii 3745 Models 130 to 17A MIP ...
Страница 66: ...Safety lxiv 3745 Models 130 to 17A MIP ...
Страница 68: ...Preface lxvi 3745 Models 130 to 17A MIP ...
Страница 70: ...Amendments lxviii 3745 Models 130 to 17A MIP ...
Страница 154: ...3745 MAPs 1 84 3745 Models 130 to 17A MIP ...
Страница 200: ...Service Processor MAPs 2 46 3745 Models 130 to 17A MIP ...
Страница 226: ...Diagnostics 3 26 3745 Models 130 to 17A MIP ...
Страница 253: ...FRU Exchange Location 01S Figure 4 31 3745 EPO Chapter 4 3745 FRU Exchange 4 27 ...
Страница 332: ...CE leaving procedure 4 106 3745 Models 130 to 17A MIP ...
Страница 338: ...Maintenance Aids A 6 3745 Models 130 to 17A MIP ...
Страница 354: ...Abbreviation X 6 3745 Models 130 to 17A MIP ...
Страница 359: ......
Страница 360: ...IBM Part Number 03F5017 Printed in Denmark by IBM Danmark A S ð3F5ð17 SY33 2ð7ð ð9 ...
Страница 361: ...Spine information IBM Models 130 to 17A IBM 3745 Communication Controller Maintenance Information Procedures ...