3745 FRU Exchange Procedure
HDD Exchange Procedure
Removal Procedure:
For physical locations,
refer to Figure 4-75.
Important
Check that the Power Control display is set to
local 3 on the control panel. If yes, go to Step 3.
If not, proceed with Step 1.
1. Press power Control until 3 (Local mode) is
displayed in the power control window.
2. Press Validate.
3. Press Service until 1 (Maintenance 1) is dis-
played in the service window.
4. Press Validate.
5. For the 3745 Model 130 to 170 go to Step 9.
For Model 17A continue, with Step 6
6. You should be logged ON on the service
processor console. If not, go to “Console Use
for Maintenance” on page 1-1 for logging ON
and return here.
7. In the MOSS-E View window, double-click on
your 3745 icon.
8. In the 3745 Menu window, double-click on the
MOSS Console option.
9. Disable the MOSS area as follows:
a. Call Menu 2.
b. Type MOF on the selection line.
c. Press SEND.
d. MOSS OFFLINE is displayed.
10. Open the front door.
11. Remove power as follows:
a. Invoke Menu 1 (see PF key line).
b. In Menu 1 type DIF in the selection area
for Disk Functions.
c. Press SEND.
d. The Disk Functions Screen is displayed.
e. Type 7 in the selection area for Power
OFF Disk/Diskette Drive.
f. Press SEND.
g. If POWER OFF SUCCESSFUL. CON-
CURRENT MAINTENANCE ACCEPTED
is displayed, go to Step 12 on page 4-57.
h. If POWER OFF UNSUCCESSFUL. CON-
CURRENT MAINTENANCE REJECTED
is displayed, do the following:
1) Inform the customer that the 3745
is to be powered OFF.
2) Press Power Off on the control panel.
3) Switch CB1 OFF. Refer to
Figure 4-75
4) Go to Step 12 on page 4-57.
Figure
4-75. HDD and CB1 Locations
4-56
3745 Models 130 to 17A: MIP
Содержание 3745 130
Страница 2: ......
Страница 10: ...viii 3745 Models 130 to 17A MIP ...
Страница 16: ...xiv 3745 Models 130 to 17A MIP ...
Страница 23: ...Safety Figure 0 2 Ground Wire Connection on Controller Expansion Safety xxi ...
Страница 25: ...Safety Figure 0 4 Ground Wire Connection Between Controller Expansions at Less than Six Meters Safety xxiii ...
Страница 36: ...Safety Figure 0 12 Schutzleiteranschluß an der Erweiterung der Steuereinheit xxxiv 3745 Models 130 to 17A MIP ...
Страница 37: ...Safety Figure 0 13 Schutzleiteranschluß zwischen angeschlossenen Erweiterungen der Steuereinheit Safety xxxv ...
Страница 46: ...Safety xliv 3745 Models 130 to 17A MIP ...
Страница 47: ...Safety Safety xlv ...
Страница 48: ...Safety xlvi 3745 Models 130 to 17A MIP ...
Страница 49: ...Safety Safety xlvii ...
Страница 50: ...Safety xlviii 3745 Models 130 to 17A MIP ...
Страница 51: ...Safety Safety xlix ...
Страница 52: ...Safety l 3745 Models 130 to 17A MIP ...
Страница 53: ...Safety Safety li ...
Страница 54: ...Safety lii 3745 Models 130 to 17A MIP ...
Страница 55: ...Safety Safety liii ...
Страница 56: ...Safety liv 3745 Models 130 to 17A MIP ...
Страница 57: ...Safety Safety lv ...
Страница 58: ...Safety lvi 3745 Models 130 to 17A MIP ...
Страница 60: ...Safety Figure 0 22 3745 Label and Power Rating Plate Locations Front lviii 3745 Models 130 to 17A MIP ...
Страница 66: ...Safety lxiv 3745 Models 130 to 17A MIP ...
Страница 68: ...Preface lxvi 3745 Models 130 to 17A MIP ...
Страница 70: ...Amendments lxviii 3745 Models 130 to 17A MIP ...
Страница 154: ...3745 MAPs 1 84 3745 Models 130 to 17A MIP ...
Страница 200: ...Service Processor MAPs 2 46 3745 Models 130 to 17A MIP ...
Страница 226: ...Diagnostics 3 26 3745 Models 130 to 17A MIP ...
Страница 253: ...FRU Exchange Location 01S Figure 4 31 3745 EPO Chapter 4 3745 FRU Exchange 4 27 ...
Страница 332: ...CE leaving procedure 4 106 3745 Models 130 to 17A MIP ...
Страница 338: ...Maintenance Aids A 6 3745 Models 130 to 17A MIP ...
Страница 354: ...Abbreviation X 6 3745 Models 130 to 17A MIP ...
Страница 359: ......
Страница 360: ...IBM Part Number 03F5017 Printed in Denmark by IBM Danmark A S ð3F5ð17 SY33 2ð7ð ð9 ...
Страница 361: ...Spine information IBM Models 130 to 17A IBM 3745 Communication Controller Maintenance Information Procedures ...