3745 MAPs
Power MAP 3945: Power OFF not Possible in Local Mode
Symptom Explanation
Conditions That Could Cause This Symptom
Power OFF is not possible in local
mode
The power control is not in local mode
Relay K1
Control Panel
PCC
Attention
Power may be present when nothing is dis-
played on the control panel.
001
When the power control is in local mode, a 3 is
displayed at the control panel.
Is the power control in local mode?
Yes No
002
– Power the 3745 OFF as follows:
Set the power control to local mode:
– Using Power Control, scroll till
the value is 3.
– Press Validate.
Press Power Off.
– Continue whit Step 003.
003
Is the 3745 still powered ON?
Yes No
004
Go to “CE Leaving Procedure” on
page 4-102.
005
Are the blowers stopped?
Yes No
006
– Suspect relay K1 located in primary
power box 01H-A2.
Refer to the YZ pages for wiring.
– Repair and re-initiate the command.
– If correct, go to “CE Leaving Procedure”
on page 4-102.
007
– Exchange the FRU group 37 on page 1-51. Go
to “3745 FRU Group Table” on page 1-49.
2-26
3745 Models 130 to 17A: MIP
Содержание 3745 130
Страница 2: ......
Страница 10: ...viii 3745 Models 130 to 17A MIP ...
Страница 16: ...xiv 3745 Models 130 to 17A MIP ...
Страница 23: ...Safety Figure 0 2 Ground Wire Connection on Controller Expansion Safety xxi ...
Страница 25: ...Safety Figure 0 4 Ground Wire Connection Between Controller Expansions at Less than Six Meters Safety xxiii ...
Страница 36: ...Safety Figure 0 12 Schutzleiteranschluß an der Erweiterung der Steuereinheit xxxiv 3745 Models 130 to 17A MIP ...
Страница 37: ...Safety Figure 0 13 Schutzleiteranschluß zwischen angeschlossenen Erweiterungen der Steuereinheit Safety xxxv ...
Страница 46: ...Safety xliv 3745 Models 130 to 17A MIP ...
Страница 47: ...Safety Safety xlv ...
Страница 48: ...Safety xlvi 3745 Models 130 to 17A MIP ...
Страница 49: ...Safety Safety xlvii ...
Страница 50: ...Safety xlviii 3745 Models 130 to 17A MIP ...
Страница 51: ...Safety Safety xlix ...
Страница 52: ...Safety l 3745 Models 130 to 17A MIP ...
Страница 53: ...Safety Safety li ...
Страница 54: ...Safety lii 3745 Models 130 to 17A MIP ...
Страница 55: ...Safety Safety liii ...
Страница 56: ...Safety liv 3745 Models 130 to 17A MIP ...
Страница 57: ...Safety Safety lv ...
Страница 58: ...Safety lvi 3745 Models 130 to 17A MIP ...
Страница 60: ...Safety Figure 0 22 3745 Label and Power Rating Plate Locations Front lviii 3745 Models 130 to 17A MIP ...
Страница 66: ...Safety lxiv 3745 Models 130 to 17A MIP ...
Страница 68: ...Preface lxvi 3745 Models 130 to 17A MIP ...
Страница 70: ...Amendments lxviii 3745 Models 130 to 17A MIP ...
Страница 154: ...3745 MAPs 1 84 3745 Models 130 to 17A MIP ...
Страница 200: ...Service Processor MAPs 2 46 3745 Models 130 to 17A MIP ...
Страница 226: ...Diagnostics 3 26 3745 Models 130 to 17A MIP ...
Страница 253: ...FRU Exchange Location 01S Figure 4 31 3745 EPO Chapter 4 3745 FRU Exchange 4 27 ...
Страница 332: ...CE leaving procedure 4 106 3745 Models 130 to 17A MIP ...
Страница 338: ...Maintenance Aids A 6 3745 Models 130 to 17A MIP ...
Страница 354: ...Abbreviation X 6 3745 Models 130 to 17A MIP ...
Страница 359: ......
Страница 360: ...IBM Part Number 03F5017 Printed in Denmark by IBM Danmark A S ð3F5ð17 SY33 2ð7ð ð9 ...
Страница 361: ...Spine information IBM Models 130 to 17A IBM 3745 Communication Controller Maintenance Information Procedures ...