c. Connect the new high speed cables to the new adapter if provided by the customer.
d. Perform basic checks via the technician port in canister A by using the “essserv1” service ID.
e. Perform the following checks in the essutils menu:
i) Option 2. Quick storage configuration check
ii) Option 3. Check enclosure cabling and paths to disks
Both options must be successful. Option 2. must show six network adapters.
Example:
localhost: Valid Network Adapter Configuration. Number of Adapter(s) found: 6
These checks are run per canister.
7. Incorporate new interfaces to the existing single master bond in canister A. (Customer task)
a. Verify two new ports, which are also called devices or interfaces, are recognized.
# ip a
# nmcli d
Example:
[root@ess3k5b ~]# nmcli d
DEVICE TYPE STATE CONNECTION bond0 bond connected bond-bond0 enp29s0f0 ethernet
connected enp29s0f0
ib0 infiniband connected bond-slave-ib0
ib1 infiniband connected bond-slave-ib1
ib2 infiniband connected bond-slave-ib2
ib3 infiniband connected bond-slave-ib3
ib4 infiniband connected bond-slave-ib4
ib5 infiniband connected bond-slave-ib5
enp1s0 ethernet unavailable -- enp29s0f1 ethernet unavailable -- enp29s0f2 ethernet
unavailable -- enp29s0f3 ethernet unavailable -- lo loopback unmanaged --
b. If this MES upgrade for EC64 (InfiniBand), issue the following commands:
# nmcli c add type infiniband ifname new interface name #1 master bond name
# nmcli c add type infiniband ifname new interface name #2 master bond name
Example:
[root@ess3k5b ~]# nmcli c add type infiniband ifname ib4 master bond0
Connection 'bond-slave-ib4' (30d93d60-0846-46c6-8baf-53e1093e67eb) successfully added.
[root@ess3k5b ~]# nmcli c add type infiniband ifname ib5 master bond0
Connection 'bond-slave-ib5' (a1c3bdfc-1b49-49a5-8966-19d6e91c4c56) successfully added.
c. If this MES upgrade for EC67 (Ethernet), issue the following commands:
# nmcli c add type ethernet ifname new interface name #1 master bond name
# nmcli c add type ethernet ifname new interface name #2 master bond name
d. To validate the newly added interfaces that are part of the bond, issue the following command:
# nmcli c
Example:
[root@ess3k5a ~]# nmcli c
NAME UUID TYPE DEVICE
enp29s0f0 ada957e2-feba-d40d-5e1d-5639f49aa2d4 ethernet enp29s0f0
bond-bond0 e26c9f46-7df6-45f8-a4d7-d322838d34da bond bond0
bond-slave-ib0 4c318f6d-d18c-45a6-b76b-9ec5daafd971 infiniband ib0
bond-slave-ib1 4bd92a1e-278f-4282-bcb2-1d7b85ab5510 infiniband ib1
bond-slave-ib2 f737ea73-27bb-4a41-b3e7-4862bac41f15 infiniband ib2
Chapter 2. Servicing 33
Содержание 3000 6.0.2
Страница 1: ...IBM Elastic Storage System 3000 6 0 2 Service Guide IBM SC28 3187 01...
Страница 4: ...Index 71 Index 71 iv...
Страница 6: ...vi...
Страница 8: ...viii...
Страница 12: ...xii IBM Elastic Storage System 3000 Service Guide...
Страница 30: ...18 IBM Elastic Storage System 3000 Service Guide...
Страница 66: ...54 IBM Elastic Storage System 3000 Service Guide...
Страница 72: ...60 IBM Elastic Storage System 3000 Service Guide...
Страница 82: ...70 IBM Elastic Storage System 3000 Service Guide...
Страница 84: ...72 IBM Elastic Storage System 3000 Service Guide...
Страница 86: ...74 IBM Elastic Storage System 3000 Service Guide...
Страница 87: ......
Страница 88: ...IBM Product Number 5765 DME 5765 DAE SC28 3187 01...