Table 5. Events for the physical disk component (continued)
Event
Event Type
Severity
Message
Description
Cause
User Action
gnr_pdisk_needanaly
sis
STATE_CHANGE
ERROR
GNR pdisk {0} needs
analysis.
The GNR pdisk has a
problem that has to be
analyzed and solved
by an expert.
The
mmlspdisk
command displays
attention
user
condition for the disk.
Contact IBM
support if you are
not sure how to
solve this problem.
gnr_pdisk_nodisks
STATE_CHANGE
INFO
No pdisks found on
this node.
No pdisks found, but
some pdisks are
expected on recovery
group nodes.
The
mmvdisk pdisk
list
command returned
no pdisks.
Run the
mmvdisk
pdisk list
command to verify if
this is correct.
gnr_pdisk_ok
STATE_CHANGE
INFO
GNR pdisk {0} is ok.
The pdisk state is ok.
N/A
N/A
gnr_pdisk_replaceab
le
STATE_CHANGE
ERROR
GNR pdisk {0} is
replaceable.
The pdisk state is
replaceable.
N/A
N/A
gnr_pdisk_sedlocked STATE_CHANGE
ERROR
GNR pdisk {0} is
locked (Self-
encrypting drive).
A self-encrypting drive
which has encryption
enabled is locked.
GNR does not have
access to any data on
the drive.
The
mmlspdisk
command shows that
the pdisk state contains
sedLocked
.
The drive must be
unlocked to be used
by GNR.
gnr_pdisk_unknown
STATE_CHANGE
WARNING
GNR pdisks are in
unknown state.
The pdisk state is
unknown.
N/A
N/A
gnr_pdisk_vanished
INFO_DELETE_E
NTITY
INFO
GNR pdisk {0} has
vanished.
A GNR pdisk listed in
the IBM Spectrum
Scale configuration
was not detected.
A GNR pdisk, listed in
the IBM Spectrum Scale
configuration as
mounted before, is not
found. This could be a
valid situation.
Run the
mmlspdisk
command to verify
that all expected
GNR pdisk exist.
gnr_pdisk_vwce
STATE_CHANGE
ERROR
GNR pdisk {0} has
volatile write cache
enabled.
Volatile write cache is
enabled on the drive.
Already committed
writes could be lost in
case of power loss.
GNR will read-only
from this disk.
The
mmlspdisk
command shows that
the pdisk state contains
VWCE.
Check why the
volatile write cache
is enabled (e.g. new
drive added with
wrong default,
wrong UDEV rules)
and fix the modes
using the
sg_wr_modes
command.
ssd_endurance_ok
STATE_CHANGE
INFO
The
ssdEndurance
Percentage
of GNR
pdisk {0} is ok.
The
ssdEndurance
Percentage
value is
ok.
N/A
N/A
ssd_endurance_warn STATE_CHANGE
WARNING
The
ssdEndurance
Percentage
of GNR
pdisk {0} is on a
warning value.
The
ssdEndurance
Percentage
value is
warning.
The
ssdEndurance
Percentage
value of
the pdisk is between 95
and 100.
SSDs have a finite
lifetime based on
the number of drive
writes per day. The
ssd-endurance-
percentage values
actually reported
will be a number
between 0 and 255.
This value indicates
the percentage of
life that is used by
the drive. The value
0 indicates that full
life remains, and
100 indicates that
the drive is at or
past its end of life.
The drive must be
replaced when the
value exceeds 100",
"state":"DEGRADED
" }.
10 IBM Elastic Storage System 3000: Service Guide
Содержание 3000 6.0.2
Страница 1: ...IBM Elastic Storage System 3000 6 0 2 Service Guide IBM SC28 3187 01...
Страница 4: ...Index 71 Index 71 iv...
Страница 6: ...vi...
Страница 8: ...viii...
Страница 12: ...xii IBM Elastic Storage System 3000 Service Guide...
Страница 30: ...18 IBM Elastic Storage System 3000 Service Guide...
Страница 66: ...54 IBM Elastic Storage System 3000 Service Guide...
Страница 72: ...60 IBM Elastic Storage System 3000 Service Guide...
Страница 82: ...70 IBM Elastic Storage System 3000 Service Guide...
Страница 84: ...72 IBM Elastic Storage System 3000 Service Guide...
Страница 86: ...74 IBM Elastic Storage System 3000 Service Guide...
Страница 87: ......
Страница 88: ...IBM Product Number 5765 DME 5765 DAE SC28 3187 01...