Table 5. Events for the physical disk component (continued)
Event
Event Type
Severity
Message
Description
Cause
User Action
gnr_nvram_erased
STATE_CHANGE
ERROR
The NVDIMM of the
pdisk {0} reports
erased image.
Image erased. The
NVDIMM contents not
persisted.
The
tslsnvramstatus
command reports
erased
failure condition
for the NVRAM drive of
the disk.
Verify that any
NVDIMM cards,
BPM encountered
any errors from FSP
log or call home
data. If any errors
are found then
replace the faulty
NVDIMM cards,
BPM or both as soon
as possible. If no
errors are found
then try to add the
drive back to RG.
gnr_nvram_error
STATE_CHANGE
ERROR
The NVDIMM of the
pdisk {0} is failed.
The NVRAM drive of
the disk is in
error
state.
The
tslsnvramstatus
command shows
failed
state for the
NVRAM drive of the disk.
N/A
gnr_nvram_ok
STATE_CHANGE
INFO
The NVDIMM of the
pdisk {0} is normal.
The NVRAM drive of
the disk is in
normal
state.
N/A
N/A
gnr_nvram_persist_e
rror
STATE_CHANGE
ERROR
The NVDIMM of the
pdisk {0} could not
persist.
NVDIMM failed to save
or restore the memory
contents.
The
tslsnvramstatus
command reports
FailToPersist
failure
condition for the NVRAM
drive of the disk.
Identify the
NVDIMM cards or
BPM, which
encountered the
errors from FSP log
or call home data,
and replace the
faulty NVDIMM
cards, BPM or both
as soon as possible.
gnr_nvram_unhealth
y
STATE_CHANGE
WARNING
The NVDIMM of the
pdisk {0} is unhealthy.
Error is detected but
save or restore might
still work for the
NVRAM drive of the
disk.
The
tslsnvramstatus
command reports
unhealthy
failure
condition for the NVRAM
drive of the disk.
Identify the
NVDIMM cards or
BPM, which
encountered the
errors from FSP log
or call home data,
and replace the
faulty NVDIMM
cards, BPM or both.
gnr_pdisk_degraded
WARNING
WARNING
GNR pdisk {0} is
degraded.
The pdisk state is
degraded.
N/A
N/A
gnr_pdisk_diagnosin
g
INFO
WARNING
GNR pdisk {0} is
diagnosing.
The pdisk state is
diagnosing.
N/A
N/A
gnr_pdisk_draining
STATE_CHANGE
ERROR
GNR pdisk {0} is
draining.
The pdisk state is
draining.
N/A
N/A
gnr_pdisk_disks
STATE_CHANGE
INFO
Pdisks found on this
node.
Pdisks found
N/A
gnr_pdisk_found
INFO_ADD_ENTI
TY
INFO
GNR pdisk {0} was
found.
A GNR pdisk listed in
the IBM Spectrum
Scale configuration
was detected.
N/A
N/A
gnr_pdisk_maintena
nce
STATE_CHANGE
WARNING
GNR pdisk {0} is in
maintenance.
The GNR pdisk is in
maintenance because
the state is either
suspended
,
serviceDrain
,
pathMaintenance
or
deleting
. This might
be caused by some
administration
commands like
mmdeldisk
.
The
mmlspdisk
command displays
maintenance
user
condition for the disk.
Complete the
maintenance action.
Contact IBM
support if you are
not sure how to
solve this problem.
gnr_pdisk_missing
STATE_CHANGE
WARNING
GNR pdisk {0} is
missing.
The pdisk state is
missing.
N/A
N/A
Chapter 1. Events 9
Содержание 3000 6.0.2
Страница 1: ...IBM Elastic Storage System 3000 6 0 2 Service Guide IBM SC28 3187 01...
Страница 4: ...Index 71 Index 71 iv...
Страница 6: ...vi...
Страница 8: ...viii...
Страница 12: ...xii IBM Elastic Storage System 3000 Service Guide...
Страница 30: ...18 IBM Elastic Storage System 3000 Service Guide...
Страница 66: ...54 IBM Elastic Storage System 3000 Service Guide...
Страница 72: ...60 IBM Elastic Storage System 3000 Service Guide...
Страница 82: ...70 IBM Elastic Storage System 3000 Service Guide...
Страница 84: ...72 IBM Elastic Storage System 3000 Service Guide...
Страница 86: ...74 IBM Elastic Storage System 3000 Service Guide...
Страница 87: ......
Страница 88: ...IBM Product Number 5765 DME 5765 DAE SC28 3187 01...