29
Chapter 2: Installing and connecting the SAN Router
ATTENTION!
Do not block ventilation openings as this will restrict air flow
around the side and front of the unit. Do not install the SAN Router in an
environment where the operating ambient temperature might exceed 104°F
(40°C).
Management port pinouts
The SAN Router has two management port connectors, an RS-232
serial connector, and an RJ45 connector.
Serial port pinout
Figure 8,
Serial port pinout
and
Table 13,
Serial port pinout description
describe the serial port pinout for the SAN Router.
Figure 8
Serial port pinout
1 2 3 4 5
6 8 9
7
i2
64
0008
Table 13
Serial port pinout description
Pin number
Signal
Comment
1
DCD
Not used in the SAN Router.
2
RxD
Input of the SAN Router.
3
TxD
Output of the SAN Router.
4
DTR
Output of the SAN Router.
5
Ground
6
DSR
Not used in the SAN Router.