PfofiBus Gateway
Command name
Byte+*1
PLC output (request)
PLC input (response)
+4 1046H
6 Position
number
Same as the value in the
request command if normal.
Deceleration read
8 0
Deceleration
data
*5
10 0
12
Axis number 0 to FH *2
14 (RSV)
Same as the value in the
request command if normal.
16 (RSV)
+4 1047H
6 Position
number
Same as the value in the
request command if normal.
8 0
0000 to 00FFH
(00FFH: maximum current)
Current-limiting value
read *6
10 0
12
Axis number 0 to FH *2
14 (RSV)
Same as the value in the
request command if normal.
16 (RSV)
+4 1048H
6 Position
number
Same as the value in the
request command if normal.
8 0
0000 to 00FFH
(00FFH: maximum current)
Load current threshold
read
10 0
12
Axis number 0 to FH *2
14 (RSV)
Same as the value in the
request command if normal.
16 (RSV)
*1 Relative byte address recognized with respect to the Gateway head address
*2 Data 00 to 0FH correspond to axis numbers (0) to (15), respectively.
*3 Signed 32-bit integer data
*4 32-bit
integer
data
*5 8-bit integer data
*6 This command is effective only with those position table numbers for which a push-current
limiting value (push-motion operation setting) other than 0 has been set.
70