PfofiBus Gateway
2. Specifications and Name of Each Part
2.1 General Specifications
Item Specification
Power supply
24 VDC
±
10%
Current consumption
300 mA max.
Group 2 only server
Communication standard
Insulated node of network powered operation type
Bit strobe
Polling
Communication specification
Master-slave connection
Cyclic
Baud rate
9.6 kbps to 12 Mbps (Set automatically)
9.6 kbps
1500 m
500 kbps
400 m
1.5 Mbps
200 m
3 Mbps
200 m
ProfiBus specifications
Communication cable length (*1)
12 Mbps
100 m
Transmission path configuration
IAI’s original multi-drop differential communication
Communication method
Half-duplex
Synchronization method
Asynchronous
Transmission path type
EIA RS485, 2-wire type
Baud rate
230.4 kbps
Error control method
No parity bit, CRC (*2)
Communication cable length
Total cable length: 100 m max.
Communication cable
Double shielded twisted-pair cable
(Recommended cable:
HK-SB/20276 X L, 2P X AWG22 by Taiyo Electric Wire & Cable)
SIO commu
ni
cation
specifications
Connected units
16 axes max.
Ambient operating temperature
0 to 40
°
C
Ambient operating humidity
85% RH or below (non-condensing)
Operating ambience
Free from corrosive or flammable gases, oil mist or powder dust
Storage temperature
-10 to 65
°
C
Storage humidity
90% RH or below (non-condensing)
Environme
n
t
Vibration durability
4.9 m/s
2
(0.5 G)
Protection class
IP20
Weight
480 g or below
*1 Refer to the operation manuals for your master unit and PLC in the case of T-branch communication.
*2 CRC: Cyclic Redundancy Check
A data error detection method commonly used in synchronous transmission.
8