PfofiBus Gateway
5.1.1 Overall address configuration
In the position number specification mode, four bytes are used by the gateway control signals, and
also by the status signals, to be input/output. For each axis, each control signal occupies two bytes in
the PLC I/O area, and a total of 48 bytes are occupied by signal inputs, and also by signal outputs,
for the entire gateway unit. The values in parentheses ( ) indicate axis numbers.
gnals, and
also by the status signals, to be input/output. For each axis, each control signal occupies two bytes in
the PLC I/O area, and a total of 48 bytes are occupied by signal inputs, and also by signal outputs,
for the entire gateway unit. The values in parentheses ( ) indicate axis numbers.
Output from PLC
⇒
Gateway Unit
⇒
Input to each axis
Output from each axis
⇒
Gateway Unit
⇒
Input to PLC
*
Byte address
Upper byte
Lower byte
Gateway control signal 0
Gateway control signal 1
Control signal (0)
Control signal (1)
Control signal (2)
Control signal (3)
Control signal (4)
Control signal (5)
Control signal (6)
Control signal (7)
Control signal (8)
Control signal (9)
Control signal (10)
Control signal (11)
Control signal (12)
Control signal (13)
Control signal (14)
Control signal (15)
Cannot be used.
Cannot be used.
Cannot be used.
Cannot be used.
Cannot be used.
Cannot be used.
Cannot be used.
Completed position
number (15)
Gateway status signal 0
Cannot be used.
Gateway status signal 1
Cannot be used.
Status signal (0)
Cannot be used.
Status signal (1)
Cannot be used.
Status signal (2)
Command position
number (0)
Status signal (3)
Command position
number (1)
Status signal (4)
Command position
number (2)
Status signal (5)
Command position
number (3)
Status signal (6)
Command position
number (4)
Status signal (7)
Command position
number (5)
Status signal (8)
Command position
number (6)
Status signal (9)
Command position
number (7)
Status signal (10)
Command position
number (8)
Status signal (11)
Command position
number (9)
Status signal (12)
Command position
number (10)
Status signal (13)
Command position
number (11)
Status signal (14)
Command position
number (12)
Status signal (15)
Command position
number (13)
Cannot be used.
Command position
number (14)
Cannot be used.
Command position
number (15)
Cannot be used.
1 byte
Cannot be used.
1 byte
Cannot be used.
1 byte
Cannot be used.
Upper byte
Lower byte
Cannot be used.
Cannot be used.
Cannot be used.
Cannot be used.
Cannot be used.
Completed position
number (0)
Completed position
number (1)
Completed position
number (2)
Completed position
number (3)
Completed position
number (4)
Completed position
number (5)
Completed position
number (6)
Completed position
number (7)
Completed position
number (8)
Completed position
number (9)
Completed position
number (10)
Completed position
number (11)
Cannot be used.
Completed position
number (12)
Completed position
number (13)
Cannot be used.
Completed position
number (14)
1 byte
* The byte address is indicated as a relative byte address from the initial byte-address byte of the
gateway.
* The byte address is indicated as a relative byte address from the initial byte-address byte of the
gateway.