Acquisition
Control Item
Setting
Range
Default
Description
Trigger
Activation
Rising Edge
Falling Edge
Level High
Level Low
Rising Edge
Select the polarity of the trigger signal (i.e., location of signal at which trigger is
applied).
Trigger OverLap
Off
Readout
Off
Select the trigger overlap operation.
Trigger Delay
(μs)
(GO-2401-PGE-
1 Only)
0 ~ 500000
0
Sets the time to delay the trigger.
Exposure Mode
Off
Timed
TriggerWidth
Timed(control via
exposure time)
Select the exposure mode.
Related Topic:
Exposure Time
GO-2400MC-
PGE-1: 38 ~
7999900 (μs)
GO-2401MC-
PGE-1: 1 ~
7999730 (μs)
GO-2400MC-
PGE-1: 18000 (μs)
GO-2401MC-
PGE-1: 24087 (μs)
Set the exposure time. The maximum value when
Trigger Mode
is set to
Off
varies depending on the [Acquisition Frame Rate Raw] value.
Exposure Auto
Off
Continuous
Off
Set whether to enable auto exposure.