GO-2400MC-PGE-1 | GO-2401MC-PGE-1 | User Manual (Ver. 1.0)
Main Functions
- 42 -
Acquisition Control
Related Setting Items:
Perform operations and configure settings related to image acquisition in Acquisition Control. The
following acquisition modes are available on the camera.
Acquisition
Mode
Description
Single Frame
Acquire a single frame when the
Acquisition Start
command is executed.
Multi Frame
Acquire the number of frames specified in Acquisition Frame Count when the
Acquisition
Start
command is executed.
Continuous
Acquire images continuously until the
Acquisition Stop
command is executed.
Change the Frame Rate
When Trigger Mode is disabled, you can change the frame rate in Acquisition Frame Rate.
Notes:
l
The shortest frame period varies depending on the ROI, Pixel Format, and Binning Mode
selected. The longest frame period is 0.125 Hz (8 sec.).
l
When Trigger Mode is enabled, the Acquisition Frame Rate setting is disabled.