GO-2400MC-PGE-1 | GO-2401MC-PGE-1 | User Manual (Ver. 1.0)
Main Functions
- 44 -
Interface FR
=
920 × 1000000 / (Height × Width × Pack value)
l
Maximum frame rate
FR_TrOloff
=
Min(Sensor FR, Interface FR)
l
Exposure time possible within frames
MaxOverlapTime_TrOloff
=
(1 / FR_TrOloff)
-
(1 / Sensor FR)
l
Exposure time outside of frame interval
NonOverlapExposureTime_TrOloff
=
ExposureTime
-
MaxOverlapTime_TrOloff
However, NonOverlapExposureTime_TrOloff calculation results that are 0 or below will be
considered as 0.
For TriggerWidth, the trigger pulse is equivalent to ExposureTime.
l
Maximum frame rate
FR_TrOloff
=
1 / {(1 / FR_TrOloff)
+
NonOverlapExposureTime_TrOloff}
When Frame Start trigger is On and Trigger OverLap is Readout
l
Maximum frame rate of sensor
Sensor FR
=
1 / {H Period × (Height
+
40)}
l
Maximum frame rate by interface
Interface FR
=
920 × 1000000 / (Height × Width × Pack value)
l
Maximum frame rate
FR_TrOloff
=
Min(Sensor FR, Interface FR)
l
Exposure time possible within frames
MaxOverlapTime_TrOlrd
=
(1 / FR_TrOloff)
-
(14 × H Period)