GO-2400MC-PGE-1 | GO-2401MC-PGE-1 | User Manual (Ver. 1.0)
Main Functions
- 66 -
Sequencer Repetition
This parameter applies to Trigger Sequencer patterns which include an index whose Sequencer ROI
Next Index is set to OFF. When the index whose Sequencer ROI Next Index is set to OFF is finished
executing, the value of Sequencer Repetition (range = 1 ~ 255) is decremented internally. If the result
of the decrement is not zero, the Trigger Sequencer pattern starts over from Index1. If the result of the
decrement is zero, the status changes to Acquisition Stop and external triggers are not accepted.
Trigger Sequencer Examples
l
User-defined Indexes (up to 128)
l
Index Structure for Trigger Sequencer