GO-2400MC-PGE-1 | GO-2401MC-PGE-1 | User Manual (Ver. 1.0)
Main Functions
- 48 -
When Exposure Mode is Timed
Example: When Trigger Source is set to Line 5 - Optical In 1 and OptIn Filter Selector is set to
10 μs
l
Trigger Overlap: OFF
t1
t2
t3
t4
GO-2400-
PGE-1
GO-2401-
PGE-1
GO-2400-
PGE-1
GO-2401-
PGE-1
GO-2400-
PGE-1
GO-2401-
PGE-1
GO-2400-
PGE-1
GO-2401-
PGE-1
8 bit
10 μs
(Min)
10 μs
(Min)
44.6 μs
65.0 μs
428.4 μs
677.7 μs
4.87 ms
-12 μs
10 bit
Packed
80.0 μs
80.0 μs
827.8 μs
840.8 μs
336 μs
247.9 μs
10 bit
10.6 ms
10500 μs
l
Trigger Overlap: ReadOut
t1
t2
t3
t4
GO-2400-
PGE-1
GO-2401-
PGE-1
GO-2400-
PGE-1
GO-2401-
PGE-1
GO-2400-
PGE-1
GO-2401-
PGE-1
GO-2400-
PGE-1
GO-2401-
PGE-1
8 bit
10 μs
(Min)
10 μs
(Min)
44.6 μs
65.4 μs
428.4 μs
677.7 μs
20471 μs
24359.3 μs
10 bit
Packed
80.0 μs
80.0 μs
827.8 μs
827.8 μs
30706 μs
30706.2 μs
10 bit
40942 μs
40943 μs