Always use a minimum of 16 AWG wire between the Power Box and Fixtures. Never exceed the
maximum distance of 50 feet from the last Fixture to the Power Box or the maximum load of 10
feet of Gen3 Fixture per PS24V75W-E05P / PW Power Box.
There is no limit of Fixtures or Power Boxes that the LL-205 Dimmer will dim, however the
distance between the LL-205 Dimmer and the last Power Box should never exceed 1000 feet
of Dimming Cable. Depending on the installation, exceeding this limit may cause flicker and/or
reduce dimming performance.
When using 0-10V control for large installations, multiple LightLink LL-205s may be connected to
the same 0-10V signal. All Fixtures installed to a single LL-205 will dim together (single zone). All
LL-205s installed to a single 0-10V signal, will dim together.
Every installation is unique and should you experience a reduction in dimming performance, you
may need to set up multiple LL-205 dimming zones.
Call 1.860.567.0708 or email [email protected] if you have further questions about dimming.