www.i2systems.com
Integrated Illumination Systems, Inc.
355 Bantam Lake Road
Morris, CT 06763 USA
tel +1.860.567.0708
fax +1.860.567.2501
[email protected]
Product information is subject to change without notice.
All brand names and product names are trademarks of i2Systems.
© 2012 i2Systems. All Rights Reserved.
Gen3
Installation Guide
i2Systems designs its Fixtures for an extended, trouble-free operating life but all electronic
equipment requires cleaning, service, and, eventually, relamping.
As part of the installation process, make sure you install the Fixture with a simple, inexpensive
means of safely accessing the Fixture in the future.
i2Systems Fixtures are not for use in applications that would require scaffolding, swing stages,
cranes, or any exotic means of accessing the Fixtures for replacement and/or relamping. You will
void the warranty if you create such an installation without first obtaining written permission from
i2Systems management.
This Fixture is rated for an operating temperature range of -20 to 40°C with a rated maximum
case temperature of 50°C. After installation, measure the case temperature to ensure it will not
exceed 50°C on any point on the housing at worst-case ambient temperature.
The Fixture has i2Systems' Active Thermal Management (ATM), which will reduce power and
therefore the case temperature if the Fixture overheats. However, you should not rely on ATM to
regulate temperature as part of the normal operation of the Fixture.
Failure to operate the Fixture within specified operating and case temperature guidelines will
void the warranty.
Situations that would cause the case temperature to exceed 50°C include:
• Areas where the ambient temperature is above 40°C
• Direct sunlight in hot climates
• Sealed compartments
• Between panes of glass or directly behind a glass window
• Inside a tight and/or insulated space
Should the case temperature exceed the maximum rating of 50°C, you can reduce power to the
Fixture by dimming it, decrease the ambient temperature, increase the airflow or volume of air
around the Fixture, and/or remove the Fixture and install a lower power Fixture.
Never install the Fixture in applications that have a greater-than-average ambient temperature
variation. Rapid heating and cooling, beyond that which occurs normally in nature, may damage
the Fixture.
If you have any questions or concerns about temperature as it relates to the Fixture, call
1.860.567.0708 before you begin the installation process.
Installation Site Considerations
Temperature Considerations