User manual
16
Introduction
of
AMF10/16
control
module
Introduction
of
iL
‐
MRS10/16
controller
panel
as
follow
1.
Start
‐
up.
Start
the
engine.
2.
Stop.
Stop
the
engine.
3.
Reset.
Clean
failure
and
alarm
state.
4.
Horn
reset.
deactivates
the
horn
5.
Mode
left.
Change
the
generator
set
mode
left
‐
handed
(MEASUREMENT
‐
AUTO
‐
MAN
‐
OFF)
6.
Mode
right.
Change
the
generator
set
mode
left
‐
handed.
(OFF
‐
MAN
‐
AUTO
‐
MEASUREMENT)
7.
Generator
set
power
on/off.
Manual
turn
on/off
the
generator
set
power
switch
8.
Generator
set
failure:
red
LED
starts
flashing
when
generator
set
failure
occur.
After
fault
reset
button
is
pressed,
goes
to
steady
light
(if
an
alarm
is
still
active)
or
is
off
(if
no
alarm
is
active)
9.
Generator
set
voltage
present:
green
LED
is
on,
if
gen
voltage
is
present
and
within
limits
10.
Connect
generator
set
power
present.
Green
LED
light,
generator
set
output
switch
is
on,
otherwise
the
green
LED
flash.
11.
Page.
Cyclic
selection
of
the
display
mode
(measurement
adjustment)
12.
Up.
Select
the
set
point,
select
the
screen
or
increase
set
value
point
13.
Down.
Select
the
set
point,
select
the
screen
or
decrease
set
value
point
14.
Enter.
Confirm
the
set
point
value
Introduction
of
function
and
operation
MRS10/16
self
‐
start
control
module
is
low
a
level
to
AMF20/25
control
module,
it
is
a
single
module
without
mains
power
measurement
function,
and
also
has
less
I/O
terminals
than
AMF20/25.
Besides,
their
other
function
and
operation
are
similar
or
same.
3.7
ATS
control
panel
3.7.1
ATS
panel
general
introduction
Our
customer
will
need
this
ATS
if
generator
set
is
used
for
self
‐
start
standby
power.
In
order
to
achieve
full
automatic
transfer
between
mains
power
and
generator
set
power
to
guarantee
all
load
present,
our
ATS
panel
select
the
best
ATS
for
all
generator
set.
And
to
the
most
possibility
to
serve
our
customers’
demand,
we
prepare
two
types
of
ATS:
MRS
and
AMF.
Besides
MRS
and
AMF
can
be
jointed
to
a
double
standby
ATS
after
a
little
change,
which
is
used
for
2
generator
sets
work
together
stand
by
mains
power.
Please
reference
relevant
details
of
ATS
for
its
function,
application,
operation
and
so
on.
Safty
Attention:
!
We
are
very
pleasure
for
your
support
of
our
product,
before
you
use
our
ATS
please
read
this
instruction
carefully.
We
mark
three
attention
parts
in
accordance
with
different
situation:
Danger:
!
If
you
do
wrong
action,
Personal
death
or
other
big
disaster
must
be
happened.
Moving
Attention
Danger
:
!
When
you
move
ATS
by
crane
or
elevator,
don’t
stand
beneath
the
ATS,
to
avoid
personal
death.
Installation
Attention
Attention:
!
All
operators
must
be
professional
electrician.
!
Cut
off
all
power
before
installation.
!
Fix
screw
in
accordance
with
TORPUE
standard.
!
Place
ATS
on
plane
in
vertical
direction.
!
Don’t
install
ATS
in
the
environment,
where
are
high
temperature,
humidor
or
filled
with
corrosion
gas.
!
Connect
neutral
pole
with
“N”
pole
while
you
install
4poles
of
ATS.
Operation
Attention
Danger:
!
Don’t
connect
energized
main
circuit
or
control
line
with
terminal.
Attention:
!
If
ATS
is
tripping,
cut
off
power
source,
find
problem
and
solve
it
at
first.
Our
company
supply
ATS
panel
should
use
for
AMF
series
generator
control
module,
from
the
diagram
you
can
see
it
is
very
easy
to
connect
cable
and
easy
install
ATS
panel.
Our
panel
can
use
in
AUTO
or
Содержание DHY34KSE
Страница 2: ...DIESEL GENERATOR Models Hyundai Engine Series Operation and Maintenance manual ...
Страница 31: ......
Страница 32: ......
Страница 33: ......
Страница 34: ......
Страница 35: ......
Страница 36: ......
Страница 37: ......
Страница 38: ......
Страница 39: ...APPENDIX E 1 ...
Страница 40: ...2 ...
Страница 41: ...3 ...
Страница 44: ...APPENDIX H ...
Страница 45: ......