Hand Torch Part Replacement Procedures
4
SmartSYNC
Service Parts and Procedures
810460
47
3.
Remove the wires from the 2-pin receptacles on the RF torch PCB. One wire at a time, push the
lever on the 2-pin wire receptacle while you pull the wire straight out of the receptacle. It can be
necessary to use some force, or push the wire into the receptacle before you pull it out. Refer to
a.
Remove the blue and black cap-sensor switch wires from the receptacle.
b.
Remove the 2 red RF wires from the receptacle.
Figure 4
– RF torch PCB connections for hand torch
4.
Put the RF torch PCB in an anti-static container, unless you are replacing the RF torch PCB.
5.
Remove the pilot terminal screw.
1
3
4
4
2
3
1
6-wire connector
2
2-pin wire receptacle
3
Blue and black cap-sensor switch wires
4
Red RF wires