![Hypertherm SmartSYNC 059719 Скачать руководство пользователя страница 85](http://html1.mh-extra.com/html/hypertherm/smartsync-059719/smartsync-059719_procedure-manual_2193772085.webp)
Mini Machine and Robotic Torch Part Replacement Procedures
6
SmartSYNC
Service Parts and Procedures
810460
85
2.
Install the pilot terminal screw as follows:
a.
Make sure that the routing of the pilot arc wire is correct.
b.
Align the ring terminal of the pilot arc wire with the slot in the torch body.
c.
Attach the pilot arc wire to the torch body with the pilot terminal screw. Tighten to 1.13 N∙m
(10 lbf∙in).
3.
Install the jumper wire connector into the receptacle. Refer to
4.
Install the wires into the 2-pin receptacles on the RF torch PCB. Refer to
for location.
a.
Push both wires of the cap-sensor switch into the 2-pin receptacle at the same time.
b.
Push both red RF wires into the 2-pin receptacle at the same time.
5.
Install the 6-wire connector into the receptacle on the RF torch PCB. Refer to
Figure 17
– RF torch PCB connections for mini machine and robotic torch
1
2
3
4
5
5
1
6-wire connector
2
2-pin wire receptacle
3
Blue and black cap-sensor switch wires
4
Stripped red RF wires
5
Jumper wire connector
Содержание SmartSYNC 059719
Страница 1: ...SmartSYNC Torches Service Parts and Procedures Guide 810460 REVISION 0 ENGLISH ...
Страница 10: ...10 810460 Service Parts and Procedures SmartSYNC ...
Страница 12: ...Before You Begin 1 12 810460 Service Parts and Procedures SmartSYNC ...
Страница 42: ...Prepare to Do the Part Replacement 3 42 810460 Service Parts and Procedures SmartSYNC ...
Страница 62: ...Hand Torch Part Replacement Procedures 4 62 810460 Service Parts and Procedures SmartSYNC ...
Страница 96: ...Torch Lead Replacement Procedures 7 96 810460 Service Parts and Procedures SmartSYNC ...
Страница 98: ...Do a Check of the Torch Assembly 8 98 810460 Service Parts and Procedures SmartSYNC ...