Hand Torch Part Replacement Procedures
4
SmartSYNC
Service Parts and Procedures
810460
55
8.
Push the RF torch PCB and cap-sensor wires into the torch handle. Make sure that the RF
torch PCB wires go around the screw boss.
9.
Use the wire routing studs to make sure that the routing of all of the wires is correct, as shown.
10.
Push the torch body fully into the torch handle.
11.
Push the torch lead fully into the torch handle.
Push the gas hose fitting flange onto the support in the handle.
Align the torch lead strain relief with the recess in the handle, and push the strain relief into
position.
12.
Push the RF wire clip onto the torch body. Make sure that the RF wire clip points up, and that
the prong of the RF wire clip is between the 2 mounting studs inside the torch handle.
1
3
4
5
2
1
RF torch PCB wires
2
Screw boss
3
Cap-sensor wires
4
Pilot arc wire
5
Start-switch wires