Assemble the machine torch
This procedure shows how to fully assemble the torch. This includes installation of all of the torch
components into the right side of the torch shell, and how to connect all of the wires.
It is not always necessary to fully disassemble the torch to the do the part replacement
procedure.
Do only the steps that are applicable.
Connect the torch components
1.
Attach the torch body to the torch lead as follows:
a.
Tighten the gas fitting with your hand.
b.
Put the torch body and torch lead on a flat surface.
c.
Make sure that the flat sides of the torch body point up and that the RF wire is in the correct
position as shown.
d.
Make sure that the white wires of the torch lead are on the opposite side from the RF torch
PCB.
1
2
1
3
1
Flat sides of the torch body
2
RF wire
3
White wires
Содержание SmartSYNC 059719
Страница 1: ...SmartSYNC Torches Service Parts and Procedures Guide 810460 REVISION 0 ENGLISH ...
Страница 10: ...10 810460 Service Parts and Procedures SmartSYNC ...
Страница 12: ...Before You Begin 1 12 810460 Service Parts and Procedures SmartSYNC ...
Страница 42: ...Prepare to Do the Part Replacement 3 42 810460 Service Parts and Procedures SmartSYNC ...
Страница 62: ...Hand Torch Part Replacement Procedures 4 62 810460 Service Parts and Procedures SmartSYNC ...
Страница 96: ...Torch Lead Replacement Procedures 7 96 810460 Service Parts and Procedures SmartSYNC ...
Страница 98: ...Do a Check of the Torch Assembly 8 98 810460 Service Parts and Procedures SmartSYNC ...