EDGE Pro Ti CNC
Instruction Manual 807660
79
Installation
Plasma connection
Table 17 Pinouts for plasma interface cable
Use the following information to order this plasma interface cable.
End A signal
Pin no.
Wire color
Pin no.
End B signal
+12 V to Tr
1 to 4
Jumper, black
Start
2
Black
4
Start
Start
10
Red
3
Start
Transfer
12
Black
12
Transfer-
Transfer
5
White
14
Ground
V-Div-
15
Black
5
V-Div-
V-Div+
8
Green
6
V-Div+
Ground
Shell
Drain wire
13
Shield
Part Number
Length
223354
3.05 m (10 ft)
223355
6.08 m (20 ft)
223048
7.62 m (25 ft)
223356
10.66 m (35 ft)
123896
15.25 m (50 ft)