102
EDGE Pro Ti CNC
Instruction Manual 807660
Maintenance and Diagnostics
Diagnostic tests
LAN and Hypernet tests
The LAN and Hypernet tests both use the same tester, shown in Figure 55.
Figure 55 LAN and Hypernet tester
Conduct this test if:
•
The CNC is not communicating with the ArcGlide or plasma system.
•
The CNC is not communicating with the local area network.
To test a LAN or Hypernet port:
1.
On the Machine Interface screen, choose the LAN or Hypernet port.
2.
Follow the instructions on the screen to plug in the tester.
3.
Choose Test on the Hypernet or LAN test screen. A message informs you if the test is successful.
If either test fails, contact your table manufacturer to replace the motherboard (141110).
Содержание EDGE Pro Ti
Страница 1: ...Instruction Manual 807660 Revision 3 EDGE Pro Ti Shape Cutting Control...
Страница 18: ...xviii Safety and compliance Safety...
Страница 48: ...48 EDGE Pro Ti CNC Instruction Manual 807660 Installation Mounting the THC...
Страница 92: ...92 EDGE Pro Ti CNC Instruction Manual 807660 Installation Hypernet and LAN cable...
Страница 144: ...144 EDGE Pro Ti CNC Instruction Manual 807660 Maintenance and Diagnostics Plasma interface assembly 228256...
Страница 149: ...EDGE Pro Ti CNC Instruction Manual 807660 149 EDGE Pro Ti Parts List PCB kits 9 8 7 6 5 4 3 2 1...
Страница 154: ...154 EDGE Pro Ti CNC Instruction Manual 807660 Wiring Diagrams Wiring diagram symbols...