Installation
Emergency stop (E-stop) connection
EDGE Pro Ti safety circuit
The EDGE Pro Ti CNC has a safety circuit that allows table manufacturers to implement E-stop or other safety measures
according the needs of their customers and their local and national safety regulations. Figure 21 illustrates this circuit.
Figure 20, illustrates an example of an E-stop design that might connect to the safety circuit within the EDGE Pro Ti
CNC through the E-stop connector on the rear panel of the CNC.
Figure 21 EDGE Pro Ti safety circuit
Power distribution
board
250 V, 10 A slow
blow fuse
1
+24 V
2
E-Stop monitor 1A
3
E-Stop monitor 1B
7
24 V coil 1B
6
24 V coil 1A
5
E-Stop monitor 2B
4
E-Stop monitor 2A
10
Field ground
9
24 V coil 2B
8
24 V coil 2A
AC
DC
Power
good
Servo board
(page 137)
current control
and
Z axis brake
M1
M2
M3
M4
60 V enable
E-stop
12 Not connected
11 Not connected
15 Not connected
14 Not connected
13 Not connected
Power good bit
E-stop input bit
I/O board to CNC
motherboard
Surge and safety
relay board
EDGE Pro Ti CNC
Relay LS1 with
force-guided
contacts
Relay LS2 with
force-guided
contacts
Normally open
Normally open
Normally closed
Normally closed
J6
CPC
EMI ground screw. Connect the ring terminal
from the E-stop cable shield.
16 Cable shield
Содержание EDGE Pro Ti
Страница 1: ...Instruction Manual 807660 Revision 3 EDGE Pro Ti Shape Cutting Control...
Страница 18: ...xviii Safety and compliance Safety...
Страница 48: ...48 EDGE Pro Ti CNC Instruction Manual 807660 Installation Mounting the THC...
Страница 92: ...92 EDGE Pro Ti CNC Instruction Manual 807660 Installation Hypernet and LAN cable...
Страница 144: ...144 EDGE Pro Ti CNC Instruction Manual 807660 Maintenance and Diagnostics Plasma interface assembly 228256...
Страница 149: ...EDGE Pro Ti CNC Instruction Manual 807660 149 EDGE Pro Ti Parts List PCB kits 9 8 7 6 5 4 3 2 1...
Страница 154: ...154 EDGE Pro Ti CNC Instruction Manual 807660 Wiring Diagrams Wiring diagram symbols...