90
EDGE Pro Ti CNC
Instruction Manual 807660
Installation
Lifter interface
Table 21 Pinouts for lifter interface cable
Use the following information to order the lifter interface cable.
Pin
number
Signal
Wire color
Dry contact circuit
1
+12 VDC
Black
2
Upper Limit switch (shared with input 11)
White
Normally
open
3
Field Common
Red
6
Lower Limit switch (shared with input 12)
Blue
3
Field Common
Red
7
Breakaway switch
Orange
3
Field Common
Red
8
Field Common
Yellow
4
Nozzle contact -12 V
Green
9
Nozzle contact sense
Violet
5
Nozzle contact common
Brown
Part Number
Length
223343
3.05 m (10 ft)
223344
6.08 m (20 ft)
223345
7.62 m (25 ft)
223346
10.66 m (35 ft)
123968
10.97 m (36 ft)
123897
15.25 m (50 ft)