Installation
7
Echion
Operator
Manual 810770
163
Ins
ta
lla
ti
on
Flush the pump and the high-pressure tubing
It is common for small pieces of metal and debris to be present in newly installed high-pressure
tubing. Flush the system to prevent damage to orifices, on/off valve parts, and other components of
the high-pressure system.
1.
Remove the cutting head and the orifice.
2.
Make sure that the on/off valve is closed.
3.
Turn
ON
the pump.
4.
Set the pressure to 345 bar (5,000 psi).
5.
On the operator interface, touch the
symbol to start the pump.
6.
Make a program that turns the valve
ON
and
OFF
in 1-second increments. Operate the program
in a loop for 15 minutes.
If a program is not available, turn the cutting head
ON
and
OFF
in 1-second intervals
for 15 minutes. This loosens debris in the high-pressure tubing.
7.
Turn
OFF
the pump.
8.
Install a ruby orifice in the cutting head. For orifice sizes, refer to
9.
Turn
ON
the pump.
10.
On the operator interface, touch the
symbol to start the pump.
11.
Increase the pressure to 2,760 bar (40,000 psi). Operate the program in a loop for 15 minutes.
12.
Increase the pressure to 4,140 bar (60,000 psi). Operate the program in a loop for 15 minutes.
If the on/off valve leaks, examine the needle, the seat, the seals, and the orifice for damage.
Replace parts, if necessary.
The pump is ready for normal operation.
CAUTION
This procedure can cause damage to the on/off valve needle and the seat and to the orifice.
Keep spare parts and orifices available.
If this pump was purchased through an OEM, the OEM could recommend a different procedure
to flush out the high-pressure tubing.
Содержание Echion
Страница 1: ...Echion Operator Manual 810770 REVISION 3 ENGLISH ...
Страница 11: ...Echion Operator Manual 810770 SC 11 Warranty Warranty ...
Страница 17: ...Echion Operator Manual 810770 SC 17 Environmental stewardship Environmental stewardship ...
Страница 28: ...Safety SC 28 810770 Operator Manual Echion Safety ...
Страница 29: ...Echion Operator Manual 810770 SC 29 Symbols and marks Symbols and marks ...
Страница 34: ...Symbols and marks SC 34 810770 Operator Manual Echion Symbols and marks ...
Страница 36: ...Optional equipment 1 36 810770 Operator Manual Echion Optional equipment ...
Страница 110: ...Parts lists 4 110 810770 Operator Manual Echion Parts lists ...
Страница 172: ...Installation 7 172 810770 Operator Manual Echion Installation ...
Страница 176: ...Touchscreen maps 9 176 810770 Operator Manual Echion Touchscreen maps ...
Страница 178: ...Touchscreen maps 9 178 810770 Operator Manual Echion ...
Страница 180: ...Touchscreen maps 9 180 810770 Operator Manual Echion ...
Страница 182: ...Touchscreen maps 9 182 810770 Operator Manual Echion ...
Страница 184: ...Touchscreen maps 9 184 810770 Operator Manual Echion ...
Страница 186: ...Touchscreen maps 9 186 810770 Operator Manual Echion ...
Страница 188: ...Touchscreen maps 9 188 810770 Operator Manual Echion ...
Страница 190: ...Technical drawings 10 190 810770 Operator Manual Echion Technical drawings ...
Страница 191: ...Technical drawings 10 Echion Operator Manual 810770 191 SCHEM ECHION HYD WTR ...
Страница 192: ...Technical drawings 10 192 810770 Operator Manual Echion ...
Страница 194: ......