9.3.1 Connection for 24V Steam Bath Exhaust Fan
(Optional)*
Connect fan cables to the designated terminals 10 and 11 (24V) in the
steam generator. The fan is protected by a 1.6 A micro fuse. The maxi-
mum contact load is 40 W.
Using Parameter D1, the exhaust fan can be operated in automatic or
continuous mode.
*: not valid for steam generators type C01 and C02
9.3.2 Connection for 24V Steam Bath Supply Fan
(Optional)*
Connect fan cables to the designated terminals 10 and 12 (24V) in the
steam generator. The fan is protected by a 1.6 A micro fuse. The maxi-
mum contact load is 40 W.
*: not valid for steam generators type C01 and C02
9.4 Cabin Light Installation (Optional)
Cabin lighting may also be connected to the steam generator.
9.4.1 Cabin Light Connection (Optional)
Connect cabin light cable to the designated terminals 13 and 14 (24 V
supply voltage) in the steam generator.
The cabin lighting is protected by a 1.6 A micro fuse. The maximum
contact load is 40 W. Switch lighting on and off using the software key
L
on the operating panel.