SPA
Page 62
9. For the Installer
Within the steam cabin, only safe low voltage (24V) is allowable.
9.1 Temperature Sensor Installation
With steam baths, a temperature sensor must be installed in the cabin.
The sensor measures the active temperature and sends the value to
the control. The recorded temperature constitutes a control variable for
controlling steam production.
Do not manipulate steam production by tampering with the tempera-
ture sensor (e.g. do not douse with cold water or cover).
General installation rules
•
Do not install the sensor close to the steam manifold
•
Mount the sensor on the wall and not in or under the wall panel-
ling
•
The best installation location for the temperature sensor is 800-
1000mm/31.5-40 inch above the bench surface (about the head
height of the steam bather)
9.1.1 Temperature Sensor Connection
Connect the temperature sensor cable to the designated terminals 6
and 7 on the HygroMatik steam generator.
Test using the table below. While the sensor has been calibrated in the
factory, subsequent adjustment within a range of -5K to +5K is possible
using a 2nd temperature gauge.
Temperature Resistance Table
Temperature in
°C/°F
Resistance in kOhm
10/50
28.5
20/68
18.5
30/86
12.3
40/104
8.3
50/122
5.8
60/140
4.1
70/158
2.9
80/176
2.1
Please note
Please note