The unit must not be operated on a DC power supply
•
The unit may only be used connected to a steam pipe that
safely transports the steam (not valid device type Mini-
Steam)
•
Regularly check that all safety and monitoring devices are
functioning normally
•
Do not remove or disable safety devices
2.1.4 Mounting, installation, maintenance, repair and
dismantling of the unit
Explosion hazard!
Ignitable gas mixture may built up in the steam cylinder due to
improper installation of essence feeding.
It is the responsibility of the unit installer and the steam bath pro-
vider to ensure that no condensated essence may drip from the
steam pipe back into the steam cylinder. Essence line entry
point in steam line must allow a 5 to 10% decline of essence line
away from steam generator.
The HygroMatik steam humidifier is IP20 protected. Make sure
that the unit is not object to dripping water in the mounting loca-
tion.
When installation is made in a room without a drain, safety pre-
cautions must be taken in order for to shut off the humidifier‘s
water supply in event of a leak.
•
Use genuine spare parts only
•
After any repair work, have qualified personnel check the
safe operation of the unit
•
Attaching or installing of
additional components
is per-
mitted only with the
written consent
of the manufacturer
•
The operator is responsible for the disposal of unit compo-
nents as required by law