MultiSystem 5060
Operating Instructions Manual
© Hydrotechnik GmbH • All rights reserved
Rev. 1.8/120307EN
Page 34 of 55
Select test procedure
1. Open
the
HYDROrun
menu:
2. Start the selection of a test procedure:
3. Highlight and select a test procedure:
HYDROrun Setup
After pressing
in the
HYDROrun
menu, a screen will be displayed,
where you may enter the
HYDROrun
release code and configure the
memory reserved for
HYDROrun
. If no release code has been entered
yet, the memory configuration is not visible. If a release code has
been entered, this cannot be selected and modified.
You may decide, how many space shall be reserved for
HYDROrun
on the SD card:
Test proc.
memory that shall be reserved for test procedure files
Measurements memory that shall be reserved for temporary meas-
urement files that may be created during the execution
of test procedures
Databases
memory that shall be reserved for databases that may
be created for intermediate or end results of test proce-
dures
This is how to configure the
HYDROrun
memory:
1. Highlight the desired memory:
2. Select the desired memory size:
3. Repeat steps 1. and 2. for the other memory types.
4. Confirm the setting with
.
Delivered test procedures
Valve compensation (German)
Setup procedure for valves. These valves have to realize an exactly defined flow under a certain pressure. After
entering operator name and the serial number of the valve, the test run starts. The setting is displayed optically
with bargraphs. A wrong setting will be displayed together with possible error causes.
Four Displays (English) –
Presentation of the measurands p1, p2, T1 and Q1 on four large-scaled displays.
Values as bargraph (English) –
Presentation of the measurands p1, p2, T1 and Q1 as bargraphs.
Cylinder alignment (English) –
Synchronity test of two lifting cylinders of a bulldozer. Additionally it will be
checked, whether suited sensors are connected to the instrument. This avoids faulty measurements due to
wrong sensors. With a bargraph the cylinder pressures p1 and p2, and the pressure difference are displayed.
The test is OK, if both pressure values are 145 bar (± 5 bar) at the final stop and the pressure difference is
smaller than 5 bar.
Nine displays (English) –
Presentation of the measurands p1, p2, p3, p4, T1, T2, Q1 and Q2 on nine large-
scaled display sections.
Di bargraph (English) –
Presentation of the measurands p1 and p2 on two large-scaled display sec-
tions and of Q1 as a bargraph.
Valve test (English) –
Serial testing of valves. It is checked whether the valves open at a defined pressure.
Pressure will be measured when a flow rate > 0.2 l/min is detected. The valve must open at a pressure of 1.5 bar
(± 0.2 bar). The test result is stored in a database that can be evaluated in the instrument and transferred to a
PC.
Arithmetic test (English) –
Graphical presentation of measured and calculated variables with
HYDRO-
gen
/
HYDROrun
.