2.2.
A/C POWER & UTILITY REQUIREMENTS
2.2.1.
The use of an improper extension cord could result in a risk of a fire or
electric shock. If an extension cord must be used, it must be UL and/or
CSA approved. Locate all cords so that they will not be stepped on,
tripped over or otherwise subjected to damage or stress. Extension cord
must be properly wired and in good electrical condition, and large
enough for the AC rating of the Power Supply as specified in this TABLE:
RECOMMENDED MINIMUM AWG SIZE FOR
EXTENSION CORDS FOR AC POWER SUPPLY
Length of cord (feet):
25
50
100
150
AWG size of cord:
16
16
16
14
2.2.2.
Refer to the Product ID Label affixed to the product and identify the
input requirements such
as ‘120Vac, 60Hz, 2Amps’. Ensure that the
product will be connected to a matching utility power rating. For
example; if product is rated at 60Hz, do not connect to a 50Hz utility.
2.2.3.
The rating of the input AC Cord, if replaced by a certified technician,
must not be less than 18Ga, 300V for 100Vac or 120Vac utilities and not
less than 18Ga, 300V for 230Vac or 240Vac utility power. Cord must be
hard usage SJT type or better, UL/CSA approved.
2.2.4.
Do not connect product to AC receptacles that share power with any
other moderate to heavy loads such as air conditioners, motors and
other common appliances. Most appliances turn on/off at random and
cause power surges and power drops that can severely affect the
product connected to that same power circuit.
2.2.5.
Inspect AC Receptacles for general wear, including loose or hanging
receptacles and be very aware of potentially worn contacts. If any heat
is felt in or around the receptacle while the AC Power Supply is
operating, this is an immediate indication of danger caused by a worn
receptacle.
2.2.6.
If making an electrical connection to a receptacle located near the body
of water intended to be treated, install both the GFCI protected
receptacle and AC Power Supply in a covered weatherproof utility box or
container and secure the AC Power Supply using the Mounting
Hardware Kit
–
supplied.
IMPORTANT:
SURGE SUPPRESSOR PROTECTION DEVICE
MUST BE USED.
A/C-Line surges are real and generated from nearby equipment and weather-related
phenomena and can cause NON-WARRANTY failure of the Power Supply.
User must
supply and install a surge suppressor rated at 1000J or greater.
These devices are
readily available from most any retail outlet.