![Hydro Bio-Science Quattro-DB Скачать руководство пользователя страница 30](http://html.mh-extra.com/html/hydro-bio-science/quattro-db/quattro-db_assembly-and-operation-instructions-manual_2191818030.webp)
Page 30
•
Illuminates continuously while charging and will remain illuminated until
the batteries have reached full charge
•
If, while charging and sunlight diminishes below the threshold where
charging is severely limited, this indicator will turn off. Charging may still
continue, but at a very slow rate.
o
Red Fault LED and Green Status LED:
•
Illumination and or Flashing of either of these LEDs would indicate a
particular mode of charging and or presence of an Error Condition. (Refer
to Section 6.7 for a list of error codes.)
•
If an Error is in effect, it may be due to a fault in the solar panel input
power section, the battery charging system, or load management where
the loads have over-discharged the battery pack.
•
Battery Under-Voltage
–
load has over-discharged the battery. Possible
contributors include: dirty solar panels, broken or loose interconnects in
the wiring, or loss of input power due to lack of sunlight (weather).
•
Battery Over or Under-Temperature. Possible contributors include
operation in very cold winter or a failed battery that is overheating.
•
A temperature sensor is installed on the battery pack
–
the cabling to the
sensor may have been broken or disconnected
•
Other conditions may contribute to this error
–
refer to the
Troubleshooting section and Customer Service for help