Systems Troubleshooting: 6-4
VaCUUM SYSTEM
Weak vacuum at wand. The gauge reads normal.
1.
Possible Cause
Solution
1.1
blockage in the hoses or
wand tube
Disconnect the hoses and check for an obstruction.
1.2
excessive
length
of
hose connected to the
truckmount
Do not attach excessive lengths of hose.
Weak vacuum
2.
Possible Cause
Solution
2.1. Air leak somewhere in the
vacuum system
Check the vacuum relief valve for proper adjustment.
Carefully check all the vacuum hoses for a cut or
break.
Check the recovery tank lid gasket.
Make sure the recovery tank drain valve is fully
closed.
2.2. The vacuum blower is
turning too slowly.
Check the rpm of the engine. Adjust as necessary to
3,000 rpm under a 14" Hg vacuum load.
2.3. The vacuum gauge is
defective.
Test the gauge and replace if necessary.
The vacuum gauge reads too high with no hoses attached
3.
Possible Cause
Solution
3.1.
The filter in recovery tank
is clogged.
Remove and clean or replace as necessary.
3.2. The hose from recovery
tank to the vacuum
blower is collapsed
internally.
Inspect and replace as necessary.
Содержание Titan H2O Kubota
Страница 2: ......
Страница 6: ...Titan H2 O Owner s Manual iv...
Страница 34: ...Machine Maintenance 4 8...
Страница 40: ...Electrical System 5 6...
Страница 46: ...Systems Troubleshooting 6 6...
Страница 48: ...Assemblies and Parts Lists 7 2 Machine Assembly View 1 of 4 Figure 7 1 610 050 743 4 5 2 X 6 7 1 11...
Страница 49: ...7 3 Assemblies and Parts Lists Machine Assembly View 2 of 4 Figure 7 2 610 050 743 11...
Страница 58: ...Assemblies and Parts Lists 7 12 Engine Assembly View 2 of 3 Figure 7 9 610 004 743 13 6 7 16 1...
Страница 59: ...7 13 Assemblies and Parts Lists Engine Assembly View 3 of 3 Figure 7 10 610 004 743 26 15 11 17 19...
Страница 80: ...How to Order Parts 8 2...
Страница 82: ...Warranty Information 9 2...